prEN 673

Glass in building - Determination of thermal transmittance (U value) - Calculation method prEN 673

Publication date:   Nov 24, 2022

General information

40.60 Close of voting   Feb 16, 2023

CEN

CEN/TC 129 Glass in building

European Norm

81.040.20   Glass in building | 91.040.20   Buildings for commerce and industry

Buying

Draft

Language in which you want to receive the document.

Scope

This European Standard specifies a calculation method to determine the thermal transmittance of glazing with flat and parallel surfaces.
This European Standard applies to uncoated glass (including glass with structured surfaces, e.g. patterned glass), coated glass and materials not transparent in the far infrared which is the case for soda lime glass products, borosilicate glass and glass ceramic. It applies also to multiple glazing comprising such glasses and/or materials. It does not apply to multiple glazing which include in the gas space sheets or foils that are far infrared transparent. The procedure specified in this European Standard determines the U value ) (thermal transmittance) in the central area of glazing.
The edge effects due to the thermal bridge through the spacer of a sealed glazing unit or through the window frame are not included. Furthermore, energy transfer due to solar radiation is not taken into account. The effects of Georgian and other bars are excluded from the scope of this European Standard.
The Standard for the calculation of the overall U value of windows, doors and shutters (see A.1) gives normative reference to the U value calculated for the glazing components according to this standard.
For the purpose of product comparison, a vertical position of the glazing is specified. In addition, U values are calculated using the same procedure for other purposes, in particular for predicting:
- heat loss through glazing;
- conduction heat gains in summer;
- condensation on glazing surfaces;
- the effect of the absorbed solar radiation in determining the solar factor (see Clause 2).
Reference should be made to [3], [4] and [5] or other European Standards dealing with heat loss calculations for the application of glazing U values determined by this standard.
A procedure for the determination of emissivity is given in EN 12898.
The rules have been made as simple as possible consistent with accuracy.

Related legislation

Legislation related to this standard

305/2011

Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec

Life cycle

PREVIOUSLY

PUBLISHED
EN 673:2011

NOW

IN_DEVELOPMENT
prEN 673
40.60 Close of voting
Feb 16, 2023