40.60 Close of voting Sep 30, 2022
CENELEC
CLC/TC 210 Electromagnetic Compatibility (EMC)
European Norm
33.040.60 Powerline telecommunications | 33.100.01 Electromagnetic compatibility in general
Draft
This part of EN 50561 specifies limits and methods of measurement of radio disturbance characteristics for in-home PLC communication apparatus that use the low-voltage power installation as the transmission medium by intentionally injecting a signal EXCLUSIVELY between two Phase (L) conductors or between one Phase (L) and Neutral (N) conductors of the low-voltage power installation.
NOTE 1 This part of EN 50561 does NOT apply to in-home PLC communication apparatus that use the low-voltage power installation as the transmission medium by intentionally injecting a signal between any Phase (L) or Neutral (N) conductors and the ground or earth (E) conductor of the low-voltage power installation.
This part of EN 50561 applies to equipment that communicate over this medium in the frequency range 1,606 5 MHz to 30 MHz.
NOTE 2 Similar equipment that communicate outside this frequency range is under study and will be covered by another European Standard.
Procedures are given for the measurement of signals generated by the equipment and limits are specified for the frequency range 9 kHz to 400 GHz. No measurement is required at frequencies where no limit is specified.
Legislation related to this standard
Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)
Directive 2014/53/EU of The European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999/5/EC
IN_DEVELOPMENT
prEN 50561-1
40.60
Close of voting
Sep 30, 2022