prEN 3475-605

Aerospace series - Cables, electrical, aircraft use - Test methods - Part 605: Wet short-circuit test

Publication date:   Oct 17, 2024

General information

40.20 DIS ballot initiated: 12 weeks   Oct 17, 2024

CEN

ASD-STAN Aerospace

European Norm

49.060   Aerospace electric equipment and systems

Buying

  Draft

PDF - €10.38

  English  



Buy

Scope

This document specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated and maintained by a contaminating fluid.
This document is intended to be used together with EN 3475-100.
The primary aim of this test is:
- to produce, in a controlled fashion, continuous failure effects, which are representative of those, which can occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs between cables; and
- to examine the aptitude of the insulation to track, to propagate electric arc to the electrical origin.
Originally defined for 115 VAC network, this test also proposes conditions for 230 VAC network. However, for 230 VAC test condition only, the test EN 3475-605 can overrule and be applied as test governance as it has been demonstrated that test EN 3475-605 is more stringent, repeatable and reproductible compared to EN 3475-604 and EN 3475-603.
Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 8). It is agreed that larger sizes need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances.
Unless otherwise specified in the technical/product standard, sizes 002, 006 and 020 cable are assessed.

Life cycle

PREVIOUSLY

PUBLISHED
EN 3475-605:2018

NOW

IN_DEVELOPMENT
prEN 3475-605
40.20 DIS ballot initiated: 12 weeks
Oct 17, 2024