45.99 Dispatch of FV draft to CCMC May 30, 2024
CEN
CEN/TC 256 Railway applications
European Norm
11.180.01 Aids for disabled and handicapped persons in general | 45.020 Railway engineering in general
This document describes the specific ‘Design for PRM use’ requirements applying to infrastructure and the assessment of those requirements. The following applies to this document:
— The definitions and requirements describe specific aspects of ‘Design for PRM use’ required by persons with disabilities and persons with reduced mobility as defined in the PRM TSI.
— This document defines elements which are universally valid for obstacle-free travelling including toilets, elements for sitting, standing and moving and clearways and internal doors. The definitions and requirements of this document are to be used for infrastructure applications.
— This document only refers to aspects of accessibility for PRM passengers; it does not define non-PRM related requirements and definitions.
— This document assumes that the infrastructure is in its defined operating condition.
— Where minimum or maximum dimensions are quoted these are absolute NOT nominal requirements.
This document contains requirements relating to 'Obstacle-free routes'.
Legislation related to this standard
Directive (EU) 2016/797 of the European Parliament and of the Council of 11 May 2016 on the interoperability of the rail system within the European Union (Text with EEA relevance)
PUBLISHED
EN 16587:2017
IN_DEVELOPMENT
FprEN 16587
45.99
Dispatch of FV draft to CCMC