Scope

The standard shall cover, regardless of if manufactured in factories or in temporary plants on site under the same conditions, the cumulative scopes:
Precast concrete solid, hollow core and multilayer wall elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element.
Products used as retaining walls are excluded from this product definition.
Precast concrete solid, hollow core and multilayer wall elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended not to be used as structural element.
Precast concrete retaining walls made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element.
Retaining walls intended to retain tanks or reservoirs of liquids are excluded from this product definition.
Precast diaphragm walls (concrete sheet piling) are also excluded from this product definition.
Precast concrete solid, hollow core and multilayer roof elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element.
Ribbed floor elements are excluded from this product definition.
Floor slabs elements are also excluded from this product definition.
Precast concrete solid, hollow core and multilayer floor elements made of lightweight concrete with an open structure intended, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element.
Floor elements with the intended use to carry traffic loads are excluded from this product
definition.
Precast concrete solid, hollow core beams made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used asstructural element.
Precast concrete solid piers made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element.
Precast concrete cladding elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as non-loadbearing elements.
Precast concrete rectangular cross-section box culverts made of lightweight concrete, and with a dry density between 400 and 2000 kg/m3, with an open structure intended not to be used as structural elements.
Precast concrete components for noise barriers made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended not to be used as structural elements