30.99 CD approved for registration as DIS Apr 29, 2024
ISO
ISO/TC 92/SC 2 Fire containment
International Standard
13.220.50 Fire-resistance of building materials and elements | 91.060.50 Doors and windows
This document, used in conjunction with ISO 834-1, specifies a method for determining the fire resistance of door and shutter assemblies designed primarily for installation within openings incorporated in vertical separating elements, such as
— hinged and pivoted doors,
— horizontally sliding and vertically sliding doors, including articulated sliding doors and sectional doors,
— steel single-skin folding shutters (un-insulated),
— other sliding, folding doors,
— tilting doors,
— rolling shutter doors,
— removable panels in walls,
— self-closing openable windows.
Requirements are included for mechanical pre-conditioning, e.g. "cycling" of door and shutter assemblies prior to the conduct of the fire-resistance test.
PUBLISHED
ISO 3008-1:2019
IN_DEVELOPMENT
ISO/CD 3008-1
30.99
CD approved for registration as DIS
Apr 29, 2024