90.20 Standard under periodical review Oct 15, 2024
ISO
ISO/TC 147/SC 2 Physical, chemical and biochemical methods
International Standard
13.060.50 Examination of water for chemical substances
Published
The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.
WITHDRAWN
ISO 8467:1986
PUBLISHED
ISO 8467:1993
90.20
Standard under periodical review