Scope

Lays down detailed specifications for the instrumentation and procedure to be used for primary calibration of accelerometers using centrifuge calibration. Applies to all types of rectilinear accelerometers, primary standards and working pick-ups. Is applicable for a frequency range from 0,7 Hz to 10 Hz and a dynamic range from 10 m/s^2 to 100 m/s^2. The limits of uncertainty applicable are ± 2 % of reading.

Life cycle

NOW

PUBLISHED
ISO 5347-8:1993
90.93 Standard confirmed
Dec 17, 2021

REVISED BY

ABANDON
ISO/PWI 5347-8