ISO 5347-8:1993

Methods for the calibration of vibration and shock pick-ups — Part 8: Primary calibration by dual centrifuge ISO 5347-8:1993

Publication date:   Dec 16, 1993

General information

90.93 Standard confirmed   Dec 17, 2021

ISO

ISO/TC 108 Mechanical vibration, shock and condition monitoring

International Standard

17.160   Vibrations, shock and vibration measurements

Buying

Published

Language in which you want to receive the document.

Scope

Lays down detailed specifications for the instrumentation and procedure to be used for primary calibration of accelerometers using centrifuge calibration. Applies to all types of rectilinear accelerometers, primary standards and working pick-ups. Is applicable for a frequency range from 0,7 Hz to 10 Hz and a dynamic range from 10 m/s^2 to 100 m/s^2. The limits of uncertainty applicable are ± 2 % of reading.

Life cycle

NOW

PUBLISHED
ISO 5347-8:1993
90.93 Standard confirmed
Dec 17, 2021

REVISED BY

ABANDON
ISO/PWI 5347-8