IEC 61347-2-2 ED3

Controlgear for electric light sources - Safety - Part 2-2: Particular requirements - Electronic step-down convertors for filament lamps IEC 61347-2-2 ED3

General information

50.60 Close of voting. Proof returned by secretariat   May 3, 2024

IEC

TC 34/SC 34C

International Standard

29.140.99   Other standards related to lamps

Scope

IEC 61347-2-2:2024 specifies safety requirements for electronic step-down convertors for use on DC supplies of up to 1 500 V or AC supplies of up to 1 000 V at 50 Hz or 60 Hz, and with a rated output voltage ≤ 50 V (RMS) at a frequency deviating from the supply frequency, or 120 V ripple free DC between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357, and other filament lamps.
This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with respect to the fourth edition of IEC 61347-1;
- introduction of dated references to the fourth edition of IEC 61347-1 as appropriate;
- deletion of the clauses and subclauses which are either no longer relevant or now covered in IEC 61347-1;
b) scope extension to 1 500 V for direct current;
c) scope clarification;
d) deletion of unused definitions;
e) revision of information and marking requirements;
f) revision of compliance conditions for the measurement of the output voltage during fault condition testing and during thermal testing.

Life cycle

PREVIOUSLY

PUBLISHED
IEC 61347-2-2:2011 ED2

NOW

IN_DEVELOPMENT
IEC 61347-2-2 ED3
50.60 Close of voting. Proof returned by secretariat
May 3, 2024