FprEN IEC 61558-2-16:2021

Safety of transformers, reactors, power supply units and combinations thereof - Part 2-16: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units for general applications FprEN IEC 61558-2-16:2021

Publication date:   Sep 2, 2019

General information

50.60 Close of voting. Proof returned by secretariat   Apr 30, 2021

CENELEC

CLC/SR 96 Transformers, reactors, power supply units, and combinations thereof

European Norm

29.180   Transformers. Reactors

Buying

Draft

Language in which you want to receive the document.

Scope

This part of IEC 61558 deals with the safety of switch mode power supply units and transformers for switch mode power supply units.
NOTE 1 Safety includes electrical, thermal and mechanical aspects.
Unless otherwise specified, from here onward, the term SMPS covers switch mode power supply units for general applications.
SMPS covered by this document are air cooled (natural or forced) independent, associated, stationary, portable, single-phase or polyphase with the rated supply voltage not exceeding 1 000 V AC, the rated supply frequency not exceeding 500 Hz, the rated internal operating frequency exceeding 500 Hz, but not exceeding 100 MHz, and the rated output not exceeding 1 kVA or 1 kW, incorporating dry-type transformers with encapsulated or non-encapsulated windings.
NOTE 2 As the maximum rated supply voltage of the internal transformer is 1 000 V AC, the maximum rated supply voltage of the switch mode power supply unit can be lower due to the type of rectification.
NOTE 3 For higher frequencies, additional requirements can be necessary. However, this document can be used for guidance.
This document is applicable to SMPS, converters and inverters without limitation of the rated output subject to an agreement between the purchaser and the manufacturer.
NOTE 4 In the context of this document, converters and inverters are considered to be SMPS.
This document applies to:
a) SMPS incorporating safety isolating transformers providing SELV, PELV, AC or DC output voltage(s) or a combination thereof in accordance with IEC 61140 and IEC 60364-4-41 for use with household and other consumer products,
b) SMPS with a maximum output voltage not exceeding 1 000 V AC or 1 415 V ripple-free DC for use with household and other consumer products, except for products covered in a),
c) This document can be used for transformers for use in SMPS (see Annex BB).
This document does not apply to:
- motor-generator sets;
- uninterruptible power supplies (UPS) in accordance with the IEC 62040 series;
- SMPS covered by IEC 61204-7 (i.e. low-voltage power supply devices DC output, performance characteristics) and DC power and distribution equipment and SMPS for use in applications covered by IEC 61010-1 and IEC 60601-1;
- lamp control gear covered by the IEC 61347 series;
- external circuits and their components intended to be connected to the input terminals and output terminals of the SMPS;
- equipment in accordance with IEC 60065, IEC 60950-1 and IEC 62368-1.
This document can also be used for guidance for products not covered by the scope of this document, the scope of IEC 61204-7 or the scope of the IEC 61347 series.
This document covers the safety requirements for:
[...]

Related legislation

Legislation related to this standard

2014/35/EU

Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits

Life cycle

PREVIOUSLY

PUBLISHED
EN 61558-2-16:2009

NOW

IN_DEVELOPMENT
FprEN IEC 61558-2-16:2021
50.60 Close of voting. Proof returned by secretariat
Apr 30, 2021

Relations

Adopted from IEC 61558-2-16:2021/COR1:2023 IDENTICAL