EN IEC 60601-2-19:2021

Medical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators EN IEC 60601-2-19:2021

Publication date:   Oct 14, 2021

General information

60.60 Standard published   Jul 16, 2021

CENELEC

CLC/TC 62 Electrical equipment in medical practice

European Norm

11.040.10   Anaesthetic, respiratory and reanimation equipment

Buying

Published

Language in which you want to receive the document.

Scope

<!-- NEW! -->IEC 60601-2-19:2020 is available as <a href="https://webstore.iec.ch/publication/67566">IEC 60601-2-19:2020 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.</br></br>IEC 60601-2-19:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT INCUBATORS, as defined in 201.3.209, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard. IEC 60601-2-19:2020 specifies safety requirements for INFANT INCUBATORS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.

IEC 60601-2-19:2020 does not apply to:

- INFANT TRANSPORT INCUBATORS; for information, see IEC 60601-2-20;

- INFANT RADIANT WARMERS; for information, see IEC 60601-2-21;

- devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35;

- INFANT PHOTOTHERAPY EQUIPMENT; for information see IEC 60601-2-50.

SKIN TEMPERATURE SENSORS which are applied to operate a BABY CONTROLLED INCUBATOR including the displayed value are not considered to be a CLINICAL THERMOMETER in the sense of the particular standard ISO 80601-2-56. IEC 60601-2-19:2020 cancels and replaces the second edition published in 2009 and Amendment 1:2016. This edition constitutes a technical revision. IEC 60601-2-19:2020 includes the following significant technical change with respect to the previous edition: re-dating of normative references.

Life cycle

NOW

PUBLISHED
EN IEC 60601-2-19:2021
60.60 Standard published
Jul 16, 2021

CORRIGENDA / AMENDMENTS

PUBLISHED
EN IEC 60601-2-19:2021/A1:2023