60.60 Standard published Oct 27, 2017
CENELEC
CLC/TC 210 Electromagnetic Compatibility (EMC)
European Norm
33.100.20 Immunity
Published
<span style="color:red">NEW!</span>IEC 61000-4-12:2017 is available as <a href="https://webstore.iec.ch/publication/61074">IEC 61000-4-12:2017 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.</br></br>IEC 61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks.
The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.
It has the status of a basic EMC publication in accordance with IEC Guide 107.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of a mathematical modelling of ring wave waveform;
b) new Annex B on selection of generators and test levels;
c) new Annex C on explanatory notes;
d) new Annex D on measurement uncertainty;
e) addition of high speed CDN;
f) addition of a calibration procedure for CDN.
Legislation related to this standard
Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)
WITHDRAWN
EN 61000-4-12:2006
PUBLISHED
EN 61000-4-12:2017
60.60
Standard published