Scope

This European Standard specifies requirements for the electromagnetic compatibility (EMC) for electrical apparatus for the detection and measurement of combustible gases, toxic 1) gases or oxygen. This standard applies to apparatus intended for use in residential, commercial and light-industrial environments as well as to apparatus intended for use in industrial environments. The apparatus may be AC-, DC- or battery powered. This European Standard is also applicable to apparatus which is intended for use in hazardous areas which may contain explosive or potentially explosive atmospheres. It covers only normal operation and does not cover safety requirements related to EMC phenomena. This standard specifies requirements for immunity tests in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges and also for emission tests. The test requirements are specified for each port considered. These requirements have been selected to ensure an adequate level of compatibility for apparatus at the appropriate locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. NOTE In special cases, situations will arise where the level of disturbances may exceed the levels specified in this standard, e.g. where an apparatus is installed in proximity to industrial, scientific or medical (ISM) equipment as specified in EN 55011 or where a hand-held transmitter is used in close proximity to an apparatus. In these instances special mitigation measures may have to be employed. Apparatus falling within the scope of this European Standard is classified as follows by the following types. – Type 1: apparatus intended for use in residential, commercial and light-industrial environments, as described in EN 61000-6-1 and EN 61000-6-3. – Type 2: apparatus intended for use in industrial environments, as described in EN 61000-6-2 and EN 61000-6-4. This European Standard does not apply to any of the following: – apparatus intended for the detection of dusts or mists in air; – scientific or laboratory based apparatus used only for analysis or measurement; – apparatus used exclusively for process measurement purposes; – apparatus for medical purposes; – apparatus intended for the direct measurement of automotive exhaust gases.

Related legislation

Legislation related to this standard

2004/108/EC

Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC

Harmonized/Supporting
2014/30/EU

Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)

Harmonized/Supporting

Life cycle

PREVIOUSLY

WITHDRAWN
EN 50270:1999

NOW

WITHDRAWN
EN 50270:2006
99.60 Withdrawal effective
Oct 20, 2017

REVISED BY

PUBLISHED
EN 50270:2015