Scope

This European Standard applies to emission and immunity aspects of EMC for electrical and electronic apparatus intended for use on railway rolling stock. EN 50121 3 2 applies for the integration of apparatus on rolling stock.
The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified.
The application of tests shall depend on the particular apparatus, its configuration, its ports, its technology and its operating conditions.
This standard takes into account the internal environment of the railway rolling stock and the external environment of the railway, and interference to the apparatus from equipment such as hand-held radio-transmitters.
If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU.
Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related standard for radio equipment.
This standard does not apply to transient emissions when starting or stopping the apparatus.
The objective of this standard is to define limits and test methods for electromagnetic emissions and immunity test requirements in relation to conducted and radiated disturbances.
These limits and tests represent essential electromagnetic compatibility requirements.
Emission requirements have been selected so as to ensure that disturbances generated by the apparatus operated normally on railway rolling stock do not exceed a level which could prevent other apparatus from operating as intended. The emission limits given in this standard take precedence over emission requirements for individual apparatus onboard the rolling stock given in other standards.
Likewise, the immunity requirements have been selected so as to ensure an adequate level of immunity for rolling stock apparatus.
The levels do not however cover all cases which may occur with an extremely low probability of occurrence in any location. Specific requirements which deviate from this standard shall be specified.
Test requirements are specified for each port considered.
These specific provisions are to be used in conjunction with the general provisions in EN 50121 1.

Related legislation

Legislation related to this standard

2004/108/EC

Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC

2008/57/EC

DIRECTIVE 2008/57/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 17 June 2008 on the interoperability of the rail system within the Community (Recast)

2014/30/EU

Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)

Life cycle

NOW

WITHDRAWN
EN 50121-3-2:2015
99.60 Withdrawal effective
Oct 24, 2019

REVISED BY

PUBLISHED
EN 50121-3-2:2016