99.60 Withdrawal effective May 26, 2010
CEN
CEN/TC 271 Surface treatment equipment - Safety
European Norm
1.1 This standard applies to machines for surface cleaning and pre-treatment - in the following called "cleaning machines" - of industrial items using liquids or vapours, i. e. stationary machines and related equipment for automated and manual cleaning and pre-treatment processes.
NOTE Cleaning machines are operated with or without heating, for example as dipping or spraying or vapour condensation process, where additional using of ultrasound is possible. These cleaning machines could be designed as single-zone or multi-zone machine, chamber machines, drum cleaning machine, low lift truck machines, round time machines or tunnel (continuous) machines.
To the extent of this document, cleaning machines for industrial items are considered as an assembly of the following equipment:
¾ pump(s) and/or other mechanical system of agitation, recirculation and spraying of cleaning liquid;
¾ forced ventilation system;
¾ heating system with temperature control;
¾ condensation system;
¾ filtration and separation system and/or solid particles extraction from the liquid;
¾ conveyor and/or handling system for the items to be processed;
¾ product handling systems and reciprocators which are part of the cleaning machine;
¾ control and/or monitoring systems;
¾ liquid handling system.
1.2 This standard deals with the common significant hazards, hazardous situations and events relevant to cleaning machines for industrial items using liquids or vapours when they are used as intended and under the conditions foreseen by the manufacturer (see clause 4). This part of the standard defines the common safety requirements for all kinds of cleaning machines for industrial items using liquids or vapours and related common devices and should be used in connection with other parts of the prEN 12921-series. The specific requirements specified in part 2 and following parts of prEN 12921 take precedence over the respective requirements in prEN 12921.
NOTE In addition, where a cleaning mac
Legislation related to this standard
WITHDRAWN
EN 12921-1:2005
99.60
Withdrawal effective
May 26, 2010
ABANDON
EN 12921-1:2005/FprA1