Centro de Ensayos Innovación y Servicios - CEIS

Insulating Liquids - Determination of the breakdown voltage at power frequency (5 – 100) kV

Empirical test procedure intended to indicate the presence of contaminants such as water and solid suspended matter, and the advisability of carrying out drying and filtration treatment.

Standards related to this testing method

Insulating liquids - Determination of the breakdown voltage at power frequency - Test method

60.60 Standard published

CLC/SR 10

Insulating liquids - Determination of the breakdown voltage at power frequency - Test method

60.60 Standard published

TC 10

Insulating liquids - Contamination by polychlorinated biphenyls (pcbs). method of determination by capillary column gas chromatography - (10 – 1000) ppm

Insulating liquids - Contamination by polychlorinated biphenyls (pcbs). method of determination by capillary column gas chromatography - (10 – 1000) ppm

Standards related to this testing method

Insulating liquids - Contamination by polychlorinated biphenyls (PCBs) - Method of determination by capillary column gas chromatography

60.60 Standard published

CLC/SR 10

Insulating Liquids - Determination of water by automatic coulometric karl fischer titration (2 – 100) ppm

Insulating Liquids - Determination of water by automatic coulometric karl fischer titration (2 – 100) ppm

Standards related to this testing method

Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration

60.60 Standard published

CLC/SR 10

Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration

60.60 Standard published

TC 10

Insulating liquids - Dielectric dissipation factor (tan δ) (0,0001 – 0,5)

Insulating liquids - Dielectric dissipation factor (tan δ) (0,0001 – 0,5)

Standards related to this testing method

Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity

60.60 Standard published

CLC/SR 10

Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity

60.60 Standard published

TC 10

Insulating liquids - Determination of neutralization coefficient (0,005 – 2 mg) KOH/g

Determination of neutralization coefficient - (0,005 – 2 mg) KOH/g - Internal procedure PT-QUI-25 based on ASTM D664

Insulating liquids - Dissolved gases by chromatography. Extraction method at vacuum with pump Toepler

Dissolved gases by chromatography. Extraction method at vacuum with pump Toepler H2 (Hydrogen) (1 - 2000) µl/l O2 (Oxygen) (8000 - 20000) µl/l N2 (Nitrogen) (15000 - 150000) µl/l CH4 (Methane) (1 - 2000) µl/l CO (Carbon monoxide) (100 - 2000) µl/l CO2 (Carbon dioxide) (500 - 8000) µl/l C2H4 (Ethylene) (1 - 2000) µl/l C2H6 (Ethane) (1 - 2000) µl/l C2H2 (Acetylene) (1 - 2000) µl/l

Standards related to this testing method

Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance

60.60 Standard published

CLC/SR 10

Insulating liquids - Dissolved gases by chromatography. Headspace method

Dissolved gases by chromatography. Headspace method. H2 (Hydrogen) (1-2000) µl/l O2 (Oxygen) (6000 - 100000) µl/l N2 (Nitrogen) (6000 - 100000) µl/l CH4 (Methane) (1 - 2000) µl/l CO (Carbon monoxide) (100 - 2000) µl/l CO2 (Carbon dioxide) (100 - 8000) µl/l C2H4 (Ethylene) (1 - 2000) µl/l C2H6 (Ethane) (1 - 2000) µl/l C2H2 (Acetylene) (1 - 2000) µl/l

Standards related to this testing method

Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance

60.60 Standard published

CLC/SR 10

Insulating liquids - Determination of 2-furfural and related compounds by HPLC. Extraction method B

Determination of 2-furfural and related compounds by HPLC. Extraction method B. 5-hydroxymethyl-2-furfural: (0,1 - 30) ppm 2-furfurialcohol: (0,1 - 30) ppm 2-furfural: (0,1 -30) ppm 2-acetylfuran: (0,1 - 30) ppm 5-methyl-2-furfural: (0,1 - 30) ppm

Standards related to this testing method

Mineral insulating oils - Methods for the determination of 2-furfural and related compounds

60.60 Standard published

CLC/SR 10

Mineral insulating oils - Sampling of gases and analysis of free and dissolved gases from oil-filled electrical equipment

Mineral insulating oils - Sampling of gases and analysis of free and dissolved gases from oil-filled electrical equipment

Standards related to this testing method

Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance

60.60 Standard published

CLC/SR 10

Method of sampling insulating liquids

99.60 Withdrawal effective

TC 10

Thermal Insulating Products - Compression behavior (Rank up to 100 kN)

Thermal Insulating Products - Compression behavior (Rank up to 100 kN)

Standards related to this testing method

Thermal insulating products for building applications - Determination of compression behaviour

99.60 Withdrawal effective

CEN/TC 88

Thermal Insulating Products - Apparent density

Thermal Insulating Products - Apparent density

Standards related to this testing method

Thermal insulating products for building applications - Determination of the apparent density

99.60 Withdrawal effective

CEN/TC 88

Thermal Insulating Products - Dimensional stability under constant normal laboratory conditions (23°C/50 %hr) using test samples

Thermal Insulating Products - Dimensional stability under constant normal laboratory conditions (23°C/50 %hr) using test samples

Standards related to this testing method

Thermal insulating products for building applications - Determination of dimensional stability under constant normal laboratory conditions (23 °C/ 50 % relative humidity)

90.60 Close of review

CEN/TC 88

Thermal Insulating Products - Dimensional stability under specified temperature and humidity conditions

Thermal Insulating Products - Dimensional stability under specified temperature and humidity conditions

Standards related to this testing method

Thermal insulating products for building applications - Determination of dimensional stability under specified temperature and humidity conditions

90.60 Close of review

CEN/TC 88

Thermal Insulating Products - Deformation under specified compressive load and temperature conditions

Thermal Insulating Products - Deformation under specified compressive load and temperature conditions

Standards related to this testing method

Thermal insulating products for building applications - Determination of deformation under specified compressive load and temperature conditions

90.60 Close of review

CEN/TC 88

Thermal Insulating Products - Compressive creep

Thermal Insulating Products - Compressive creep

Standards related to this testing method

Thermal insulating products for building applications - Determination of compressive creep

99.60 Withdrawal effective

CEN/TC 88

Thermal Insulating Products - Tensile strength perpendicular to faces (Rank up to 100 kN)

Thermal Insulating Products - Tensile strength perpendicular to faces (Rank up to 100 kN)

Standards related to this testing method

Thermal insulating products for building applications - Determination of tensile strength perpendicular to faces

90.60 Close of review

CEN/TC 88

Thermal Insulating Products - Tensile strength parallel to faces (Rank up to 100 kN)

Thermal Insulating Products - Tensile strength parallel to faces (Rank up to 100 kN)

Standards related to this testing method

Thermal insulating products for building applications - Determination of tensile strength parallel to faces

99.60 Withdrawal effective

CEN/TC 88

Thermal Insulating Products - Short term water absorption by partial immersion

Thermal Insulating Products - Short term water absorption by partial immersion

Standards related to this testing method

Thermal insulating products for building applications - Determination of short term water absorption by partial immersion

99.60 Withdrawal effective

CEN/TC 88

Thermal insulating products for building applications - Determination of short-term water absorption by partial immersion (ISO 29767:2019)

60.60 Standard published

CEN/TC 88

Thermal Insulating Products - Linear dimensions of test specimens

Thermal Insulating Products - Linear dimensions of test specimens

Standards related to this testing method

Thermal insulating products for building applications - Determination of linear dimensions of test specimens

99.60 Withdrawal effective

CEN/TC 88

Thermal insulating products for building applications — Determination of linear dimensions of test specimens

95.99 Withdrawal of Standard

ISO/TC 163/SC 1

Thermal Insulating Products - Water vapor transmission properties

Thermal Insulating Products - Water vapour transmission properties

Standards related to this testing method

Thermal insulating products for building applications - Determination of water vapour transmission properties

90.60 Close of review

CEN/TC 88

Thermal Insulating Products - Long term water absorption by immersion

Thermal Insulating Products - Long term water absorption by immersion

Standards related to this testing method

Thermal insulating products for building applications - Determination of long term water absorption by immersion

99.60 Withdrawal effective

CEN/TC 88

Thermal insulating products for building applications - Determination of long-term water absorption by immersion (ISO 16535:2019)

60.60 Standard published

CEN/TC 88

Thermal Insulating Products - Long term water absorption by diffusion

Thermal Insulating Products - Long term water absorption by diffusion

Standards related to this testing method

Thermal insulating products for building applications - Determination of long term water absorption by diffusion

99.60 Withdrawal effective

CEN/TC 88

Thermal insulating products for building applications - Determination of long-term water absorption by diffusion (ISO 16536:2019)

60.60 Standard published

CEN/TC 88

Thermal Insulating Products - Bending behaviors. (Rank up to 100 kN)

Thermal Insulating Products - Bending behaviour. (Rank up to 100 kN)

Standards related to this testing method

Thermal insulating products for building applications - Determination of bending behaviour

90.60 Close of review

CEN/TC 88

Thermal Insulating Products - Shear behavior

Thermal Insulating Products - Shear behavior

Standards related to this testing method

Thermal insulating products for building applications - Determination of shear behaviour

90.60 Close of review

CEN/TC 88

Thermal Insulating Products - Freeze-thaw resistance

Thermal Insulating Products - Freeze-thaw resistance

Standards related to this testing method

Thermal insulating products for building applications - Determination of freeze-thaw resistance

99.60 Withdrawal effective

CEN/TC 88

Thermal Insulating Products - Behavior under point load (Rank up to 100 kN)

Thermal Insulating Products - Behavior under point load (Rank up to 100 kN)

Standards related to this testing method

Thermal insulating products for building applications - Determination of behaviour under point load

90.60 Close of review

CEN/TC 88

Thermal Insulating Products - Determination of thickness for floating floor insulating products

Thermal Insulating Products - Determination of thickness for floating floor insulating products

Standards related to this testing method

Thermal insulating products for building applications - Determination of thickness for floating floor insulating products

99.60 Withdrawal effective

CEN/TC 88

Thermal Insulating Products - Thermal resistance and thermal conductivity by means of guarded hot plate and heat flow meter method

Thermal resistance and thermal conductivity by means of guarded hot plate and heat flow meter method (0,15 – 15 m2·K/W) (0,01– 0,2 W/(m·K)) EN 12667; EN 12939; ISO 8301; ASTM C518

Standards related to this testing method

Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Thick products of high and medium thermal resistance

90.92 Standard to be revised

CEN/TC 89

Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance

90.92 Standard to be revised

CEN/TC 89

Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter apparatus

90.60 Close of review

ISO/TC 163/SC 1

Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter apparatus — Amendment 1

60.60 Standard published

ISO/TC 163/SC 1

Thermal insulating products. Elastic materials used on floating floor systems - Dynamic stiffness (pulse method)

Thermal insulating products. Elastic materials used on floating floor systems - Dynamic stiffness (pulse method)

Standards related to this testing method

Acoustics - Determination of dynamic stiffness - Part 1: Materials used under floating floors in dwellings

90.93 Standard confirmed

CEN/TC 126

Thermal insulating products. Materials for acoustic application - Air flow resistance. Direct air flow Method

Thermal insulating products. Materials for acoustic application - Air flow resistance. Direct air flow Method

Standards related to this testing method

Acoustics - Materials for acoustical applications - Determination of airflow resistance (ISO 9053:1991)

99.60 Withdrawal effective

CEN/TC 126

Acoustics - Determination of airflow resistance - Part 1: Static airflow method (ISO 9053-1:2018)

60.60 Standard published

CEN/TC 126

Thermal insulating products (preformed pipe insulation) - Water vapour transmission properties

Thermal insulating products (preformed pipe insulation) - Water vapour transmission properties

Standards related to this testing method

Thermal insulating products for building equipment and industrial installations - Determination of water vapour transmission properties of preformed pipe insulation

99.60 Withdrawal effective

CEN/TC 88

Thermal insulating products In-situ formed sprayed rigid polyurethane - Density by immersion method

Thermal insulating products In-situ formed sprayed rigid polyurethane - Density by immersion method

Standards related to this testing method

Thermal insulating products for buildings - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 2: Specification for the installed insulation products

90.60 Close of review

CEN/TC 88

Expanded polystyrene (EPS) elements for floors with concrete applied in situ - Resistance to puncture - UNE 53974

Test according to UNE 53974

Rigid cellular plastics - Determination of the volume percentage of closed and open cells

Rigid cellular plastics - Determination of the volume percentage of closed and open cells

Standards related to this testing method

Rigid cellular plastics - Determination of the volume percentage of open cells and of closed cells (ISO 4590:2016)

60.60 Standard published

CEN/TC 249

Conductors of insulated cables - Electrical resistance - Dimensional limits of circular cables

Electrical material, cables, conductors and electrical equipment - Conductors of insulated cables - Electrical resistance - Dimensional limits of circular cables

Standards related to this testing method

Conductors of insulated cables

60.60 Standard published

CLC/TC 20

Conductors of insulated cables

60.60 Standard published

CLC/TC 20

Conductors of insulated cables

99.60 Withdrawal effective

TC 20

Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - General requirements

Electrical material, cables, conductors and electrical equipment - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - General requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements

90.93 Standard confirmed

CLC/TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements

99.60 Withdrawal effective

TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements

60.60 Standard published

TC 20

Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Testing Methods

Electrical material, cables, conductors and electrical equipment - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Testing Methods

Standards related to this testing method

Electrical test methods for low voltage energy cables

90.93 Standard confirmed

CLC/TC 20

Non electrical test methods for low voltage energy cables

90.93 Standard confirmed

CLC/TC 20

Single core cables with crosslinked silicone rubber insulation - Particular requirements

Electrical material, cables, conductors and electrical equipment - Single core cables with crosslinked silicone rubber insulation - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation

90.93 Standard confirmed

CLC/TC 20

Flexible cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Flexible cables - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

90.93 Standard confirmed

CLC/TC 20

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

60.60 Standard published

CLC/TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

99.60 Withdrawal effective

TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

60.60 Standard published

TC 20

Cables for arc welding - Particular requirements

Electrical material, cables, conductors and electrical equipment - Cables for arc welding - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding

90.93 Standard confirmed

CLC/TC 20

Heat resistant cables for general applications for conductors - temperature up to 110⁰C - Particular requirements

Electrical material, cables, conductors and electrical equipment - Heat resistant cables for general applications for conductors - temperature up to 110⁰C - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation

90.93 Standard confirmed

CLC/TC 20

Cables with crosslinked elastomeric insulation for decorative chains - Particular requirements

Electrical material, cables, conductors and electrical equipment - Cables with crosslinked elastomeric insulation for decorative chains - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains

90.93 Standard confirmed

CLC/TC 20

Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke - Particular requirements including UNE 21027-9

Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke - Particular requirements. Standards: UNE 21027-9 and EN 50525-3-41

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke

90.93 Standard confirmed

CLC/TC 20

Flexible cables with crosslinked elastomeric insulation - Particular requirements

Electrical material, cables, conductors and electrical equipment - Flexible cables with crosslinked elastomeric insulation - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

90.93 Standard confirmed

CLC/TC 20

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

60.60 Standard published

CLC/TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

99.60 Withdrawal effective

TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

60.60 Standard published

TC 20

Cables with crosslinked EVA insulation - Particular requirements

Electrical material, cables, conductors and electrical equipment - Cables with crosslinked EVA insulation - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

90.93 Standard confirmed

CLC/TC 20

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

60.60 Standard published

CLC/TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

99.60 Withdrawal effective

TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

60.60 Standard published

TC 20

Heat Resistant flexibles cables with crosslinked EPR insulation - Particular requirements

Electrical material, cables, conductors and electrical equipment - Heat Resistant flexible cables with crosslinked EPR insulation - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

90.93 Standard confirmed

CLC/TC 20

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

60.60 Standard published

CLC/TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

99.60 Withdrawal effective

TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

60.60 Standard published

TC 20

Flexible cables with crosslinked reticulated composition and with low emission of smoke and corrosive gases - Particular requirements

Electrical material, cables, conductors and electrical equipment - Flexible cables with crosslinked reticulated composition and with low emission of smoke and corrosive gases - Particular requirements

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

90.93 Standard confirmed

CLC/TC 20

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

60.60 Standard published

CLC/TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

99.60 Withdrawal effective

TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

60.60 Standard published

TC 20

Flexible cables with halogen-free crosslinked insulation, and low emission of smoke - Particular requirements

Electrical material, cables, conductors and electrical equipment - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke - Particular requirements - EN 50525-3-21

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke

60.60 Standard published

CLC/TC 20

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke

90.93 Standard confirmed

CLC/TC 20

High flexibility braided cables with crosslinked elastomeric insulation - Particular requirements

Electrical material, cables, conductors and electrical equipment - High flexibility braided cables with crosslinked elastomeric insulation - Particular requirements - EN 50525-2-22

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation

90.93 Standard confirmed

CLC/TC 20

Multicore cables with crosslinked silicone rubber insulation - Particular requirements

Electrical material, cables, conductors and electrical equipment - Multicore cables with crosslinked silicone rubber insulation - Particular requirements - EN 50525-2-83

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation

90.93 Standard confirmed

CLC/TC 20

Water resistant cables with polychloropreno, or equivalent synthetic crosslinked elastomeric insulation - Particular requirements

Electrical material, cables, conductors and electrical equipment - Water resistant cables with polychloropreno, or equivalent synthetic crosslinked elastomeric insulation - Particular requirements EN 50525-2-21; IEC 60245-4:1994+ AMD1:1997+AMD2:2003 Ed.2.2; IEC 60245-4:2011 Ed.3

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

90.93 Standard confirmed

CLC/TC 20

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation

60.60 Standard published

CLC/TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

99.60 Withdrawal effective

TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables

60.60 Standard published

TC 20

Cables with thermoplastic insulation of nominal voltage Uo/U up to and including 450/750 V - General requirements

Electrical material, cables, conductors and electrical equipment - Cables with thermoplastic insulation of nominal voltage Uo/U up to and including 450/750 V - General requirements - EN 50525-1; IEC 60227-1:2007 Ed.3.0; IEC 60245-1:2003+AMD1:2007 Ed.3

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements

90.93 Standard confirmed

CLC/TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements

99.60 Withdrawal effective

TC 20

Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements

60.60 Standard published

TC 20

Cables with thermoplastic insulation of nominal voltage Uo/U up to and including 450/750 V - Testing method

Electrical material, cables, conductors and electrical equipment - Cables with thermoplastic insulation of nominal voltage Uo/U up to and including 450/750 V - Testing method - EN 50395; EN 50396

Standards related to this testing method

Non electrical test methods for low voltage energy cables

60.60 Standard published

CLC/TC 20

Electrical test methods for low voltage energy cables

60.60 Standard published

CLC/TC 20

Electrical test methods for low voltage energy cables

90.93 Standard confirmed

CLC/TC 20

Non electrical test methods for low voltage energy cables

90.93 Standard confirmed

CLC/TC 20

Single core non-sheathed cables with thermoplastic PVC insulation- Particular requirements

Electrical material, cables, conductors and electrical equipment - Single core non-sheathed cables with thermoplastic PVC insulation- Particular requirements - EN 50525-2-31; IEC 60227-3:1993+AMD1:1997 Ed.2.1

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation

90.93 Standard confirmed

CLC/TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring

60.60 Standard published

TC 20

Sheathed cables for fixed wiring - Particular requirements

Electrical material, cables, conductors and electrical equipment - Sheathed cables for fixed wiring - Particular requirements - HD 21.4S2; IEC 227-4:1979 MOD

Standards related to this testing method

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring

99.60 Withdrawal effective

CLC/TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring

99.60 Withdrawal effective

TC 20

Flexible cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Flexible cables - Particular requirements - EN 50525-2-11; EN 50525-2-71; (CEIS: UNE 21031); IEC 60227-5:1997+AMD1:1997+AMD 2:2003 Ed.2.2; IEC 60227-5:2011 Ed.3.0

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation

90.93 Standard confirmed

CLC/TC 20

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation

90.93 Standard confirmed

CLC/TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)

99.60 Withdrawal effective

TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)

99.60 Withdrawal effective

TC 20

Single core non-sheathed for conductor temperature of 90°C - Particular requirements

Electrical material, cables, conductors and electrical equipment - Single core non-sheathed for conductor temperature of 90°C - Particular requirements - EN 50525-2-31; IEC 60227-3:1993+AMD1:1997 Ed.2.1

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation

90.93 Standard confirmed

CLC/TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring

60.60 Standard published

TC 20

Cables without cover for decorative chains - Particular requirements

Electrical material, cables, conductors and electrical equipment - Cables without cover for decorative chains - Particular requirements - HD 21.8 S2

Standards related to this testing method

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 8: Single core non-sheathed cables for decorative chains

99.60 Withdrawal effective

CLC/TC 20

Single core non-sheathed cable for installation at low temperatures - Particular requirements

Electrical material, cables, conductors and electrical equipment - Single-core non-sheathed cable for installation at low temperatures - Particular requirements - HD 21.8 S2

Standards related to this testing method

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 8: Single core non-sheathed cables for decorative chains

99.60 Withdrawal effective

CLC/TC 20

Extensibles cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Extensibles cables - Particular requirements - EN 50525-2-12

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads

90.93 Standard confirmed

CLC/TC 20

Cables for luminaires - Particular requirements

Electrical material, cables, conductors and electrical equipment - Cables for luminaires - Particular requirements - EN 50525-2-72

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation

90.93 Standard confirmed

CLC/TC 20

Heat resistant flexible cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Heat resistant flexible cables - Particular requirements - EN 50525-2-11; IEC 60227-5:1997+AMD1:1997+AMD2:2003 Ed.2.2; IEC 60227-5:2011 Ed.3.0

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation

90.93 Standard confirmed

CLC/TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)

99.60 Withdrawal effective

TC 20

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)

99.60 Withdrawal effective

TC 20

Oil resistant control cables with thermoplastic PVC insulation - Particular requirements

Electrical material, cables, conductors and electrical equipment - Oil resistant control cables with thermoplastic PVC insulation - Particular requirements - EN 50525-2-51

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation

90.93 Standard confirmed

CLC/TC 20

Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke - Particular requirements

Electrical material, cables, conductors and electrical equipment - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke - Particular requirements - EN 50525-3-11

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke

90.93 Standard confirmed

CLC/TC 20

Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke - Particular requirements

Electrical material, cables, conductors and electrical equipment - Single-core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke - Particular requirements - EN 50525-3-31

Standards related to this testing method

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke

90.93 Standard confirmed

CLC/TC 20

Cables - Electrical test methods for low voltage energy cables

Electrical material, cables, conductors and electrical equipment - Cables - Electrical test methods for low voltage energy cables - EN 50395

Standards related to this testing method

Electrical test methods for low voltage energy cables

60.60 Standard published

CLC/TC 20

Electrical test methods for low voltage energy cables

90.93 Standard confirmed

CLC/TC 20

Cables - Non-electrical test methods for low voltage energy cables

Electrical material, cables, conductors and electrical equipment - Cables - Non-electrical test methods for low voltage energy cables - EN 50396

Standards related to this testing method

Non electrical test methods for low voltage energy cables

60.60 Standard published

CLC/TC 20

Non electrical test methods for low voltage energy cables

90.93 Standard confirmed

CLC/TC 20

Flexible cables for elevators and service lifts - Particular requirements

Electrical material, cables, conductors and electrical equipment - Flexible cables for elevators and service lifts - Particular requirements - EN 50214

Standards related to this testing method

Flat polyvinyl chloride sheathed flexible cables

60.60 Standard published

CLC/TC 20

Flat polyvinyl chloride sheathed flexible cables

60.60 Standard published

CLC/TC 20

Flexibles cables for moveable services isolated with rubber of ethylene-propylene and covering reinforced of polychloroprene

Electrical material, cables, conductors and electrical equipment - Flexibles cables for moveable services isolated with rubber of ethylene-propylene and covering reinforced of polychloroprene - Particular requirements - UNE 21150

Cables for AGL constant current series circuits Particular requirements

Cables for AGL constant current series circuits Particular requirements - UNE 21161

Power cables for submergible pumps - Particular requirements - UNE 21166

Power cables for submergible pumps - Particular requirements - UNE 21166

Cables and their accessories - Impulse test

Electrical material, cables, conductors and electrical equipment - Cables and their accessories - Impulse test - EN IEC 60230; IEC 60230

Standards related to this testing method

Impulse tests on cables and their accessories

60.60 Standard published

CLC/TC 20

Impulse tests on cables and their accessories

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Measurement of insulation thickness

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Measurement of insulation thickness - EN 60811-201; IEC 60811-201

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness

60.60 Standard published

TC 20

Amendment 1 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Measurement of thickness of non-metallic cover

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Measurement of thickness of non-metallic cover - EN 60811-202; IEC 60811-202

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath

60.60 Standard published

TC 20

Amendment 1 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Measurement of the external dimensions

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Measurement of the external dimensions - EN 60811-203; IEC 60811-203

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Mechanical properties of insulating and sheathing compounds

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Mechanical properties of insulating and sheathing compounds - EN 60811-501; IEC 60811-501

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds

60.60 Standard published

TC 20

Amendment 1 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Thermal ageing methods: - Ageing in an air oven + Ageing in an air bomb

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Thermal ageing methods: - Ageing in an air oven + Ageing in an air bomb - EN 60811-401; EN 60811-412; IEC 60811-401; IEC 60811-412

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 412: Miscellaneous tests - Thermal ageing methods - Ageing in an air bomb

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven

60.60 Standard published

TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 412: Miscellaneous tests - Thermal ageing methods - Ageing in an air bomb

60.60 Standard published

TC 20

Amendment 1 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Ageing procedures and evaluation of test results

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Ageing procedures and evaluation of test results - EN 50618; EN 60216-1

Standards related to this testing method

Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results

60.60 Standard published

CLC/SR 112

Electric cables for photovoltaic systems

90.93 Standard confirmed

CLC/TC 20

Insulating materials and cover of electrical cables - Water absorption test

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Water absorption test - EN 60811-402; IEC 60811-402

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Shrinkage test for insulations

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Shrinkage test for insulations - EN 60811-502; IEC 60811-502

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Shrinkage test for sheaths

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Shrinkage test for sheaths - EN 60811-503; IEC 60811-503

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Methods for determining the density

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Methods for determining the density - EN 60811-606; IEC 60811-606

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Bending test at low temperature

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Bending test at low temperature - EN 60811-504; IEC 60811-504

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Elongation at low temperature

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Elongation at low temperature - EN 60811-505; IEC 60811-505

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths

60.60 Standard published

TC 20

Insulating materials and cover of electrical cables - Impact test at low temperature for insulations and sheaths

Electrical material, cables, conductors and electrical equipment - Insulating materials and cover of electrical cables - Impact test at low temperature for insulations and sheaths - EN 60811-506; IEC 60811-506

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths

60.60 Standard published

TC 20

Insulation and cover of electrical cables: Elastomeric materials - Ozone resistance test on cross-linked compounds

Electrical material, cables, conductors and electrical equipment - Insulation and cover of electrical cables: Elastomeric materials - Ozone resistance test on cross-linked compounds - EN 60811-403; IEC 60811-403

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds

60.60 Standard published

TC 20

Insulation and cover of electrical cables: Elastomeric materials - Mineral oil immersion test for sheaths

Electrical material, cables, conductors and electrical equipment - Insulation and cover of electrical cables: Elastomeric materials - Mineral oil immersion test for sheaths - EN 60811-404; IEC 60811-404

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths

60.60 Standard published

TC 20

Insulation and cover of electrical cables: Elastomeric materials - Hot set test for cross-linked materials

Electrical material, cables, conductors and electrical equipment - Insulation and cover of electrical cables: Elastomeric materials - Hot set test for cross-linked materials - EN 60811-507; IEC 60811-507

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials

60.60 Standard published

TC 20

Insulation and covers of electrical cables: PVC mixtures - Pressure test at High temperature for insulation and sheaths

Electrical material, cables, conductors and electrical equipment - Insulation and covers of electrical cables: PVC mixtures - Pressure test at High temperature for insulation and sheaths - EN 60811-508; IEC 60811-508

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths

60.60 Standard published

TC 20

Amendment 1 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths

60.60 Standard published

TC 20

Insulation and covers of electrical cables: PVC mixtures - Test for resistance of insulations and sheaths to cracking (heat shock test)

Electrical material, cables, conductors and electrical equipment - Insulation and covers of electrical cables: PVC mixtures - Test for resistance of insulations and sheaths to cracking (heat shock test) - EN 60811-509; IEC 60811-509

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)

60.60 Standard published

TC 20

Amendment 1 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)

60.60 Standard published

TC 20

Insulation and covers of electrical cables: PVC mixtures - Test for resistance of insulations and sheaths to cracking (heat shock test)

Electrical material, cables, conductors and electrical equipment - Insulation and covers of electrical cables: PVC mixtures - Test for resistance of insulations and sheaths to cracking (heat shock test) - EN 60811-405; IEC 60811-405

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths

60.60 Standard published

TC 20

Insulation and covers of electrical cables: PVC mixtures - Test for resistance of insulations and sheaths to cracking (heat shock test)

Electrical material, cables, conductors and electrical equipment - Insulation and covers of electrical cables: PVC mixtures - Test for resistance of insulations and sheaths to cracking (heat shock test) - EN 60811-409; IEC 60811-409

Standards related to this testing method

Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths

60.60 Standard published

CLC/TC 20

Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths

60.60 Standard published

TC 20

Electric cables - Tests of behaviour to fire: Exposing to the flame

Electrical material, cables, conductors and electrical equipment - Electric cables - Tests of behaviour to fire: Exposing to the flame - EN 60332-1-1; IEC 60332-1-1; EN 60332-1-2; IEC 60332-1-2; EN 60332-1-3; IEC 60332-1-3; EN 60332-2-1; IEC 60332-2-1; EN 60332-2-2; IEC 60332-2-2;

Standards related to this testing method

Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

60.60 Standard published

TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles

60.60 Standard published

TC 20

Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus

60.60 Standard published

TC 20

Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame

60.60 Standard published

TC 20

Amendment 1 - Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus

60.60 Standard published

TC 20

Amendment 1 - Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

60.60 Standard published

TC 20

Amendment 1 - Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles

60.60 Standard published

TC 20

Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus

60.60 Standard published

TC 20

Electric cables - Test of non propagation of fire

Electrical material, cables, conductors and electrical equipment - Electric cables - Test of non propagation of fire - EN 60332-3-10; IEC 60332-3-10; EN 60332-3-21; IEC 60332-3-21; EN 60332-3-22; IEC 60332-3-22; EN 60332-3-23; IEC 60332-3-23; EN 60332-3-24; IEC 60332-3-24; EN 60332-3-25; IEC 60332-3-25

Standards related to this testing method

Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus

99.60 Withdrawal effective

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D

60.60 Standard published

CLC/TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R

60.60 Standard published

TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A

60.60 Standard published

TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B

60.60 Standard published

TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C

60.60 Standard published

TC 20

Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D

60.60 Standard published

TC 20

Electric cables - Determination of the amount of halogen acid gas removed and the degree of acidity (corrosivity) on gases evolved during combustion of gases

Electrical material, cables, conductors and electrical equipment - Electric cables - Determination of the amount of halogen acid gas removed and the degree of acidity (corrosivity) on gases evolved during combustion of gases - EN 60754-1; IEC 60754-1; EN 60754-2; IEC 60754-2

Standards related to this testing method

Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content

60.60 Standard published

CLC/TC 20

Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity

60.60 Standard published

CLC/TC 20

Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content

60.60 Standard published

TC 20

Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity

60.60 Standard published

TC 20

Electric cables - Measurement of smoke density of cables burning

Electrical material, cables, conductors and electrical equipment - Electric cables - Measurement of smoke density of cables burning - EN 61034-1; IEC 61034-1; EN 61034-2; IEC 61034-2

Standards related to this testing method

Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

60.60 Standard published

CLC/TC 20

Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

60.60 Standard published

CLC/TC 20

Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

60.60 Standard published

CLC/TC 20

Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

60.60 Standard published

CLC/TC 20

Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

60.60 Standard published

CLC/TC 20

Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

60.60 Standard published

TC 20

Amendment 1 - Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

60.60 Standard published

TC 20

Electric cables - Method of test for resistance to fire of unprotected small cables for use in emergency circuits

Electrical material, cables, conductors and electrical equipment - Electric cables - Method of test for resistance to fire of unprotected small cables for use in emergency circuits - EN 50200

Standards related to this testing method

Method of test for resistance to fire of unprotected small cables for use in emergency circuits

90.93 Standard confirmed

CLC/TC 20

Electric cables - Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits

Electrical material, cables, conductors and electrical equipment - Electric cables - Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits; EN 50362

Standards related to this testing method

Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits

99.60 Withdrawal effective

CLC/TC 20

Electric cables - Heat release and smoke production measurement

Electrical material, cables, conductors and electrical equipment - Electric cables - Heat release and smoke production measurement - EN 50399

Standards related to this testing method

Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results

60.60 Standard published

CLC/TC 20

Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results

60.60 Standard published

CLC/TC 20

Electric cables - Test on high voltage cables

Electrical material, cables, conductors and electrical equipment - Electric cables - Test on high voltage cables - IEC 60502-1:2004 except section 18.18 and 18.19; IEC 60502-1:2004/A1:2009; IEC 60502-2 except section 19.20, 19.21 and 20 corresponding to 2014 version or equivalent sections in later versions

Standards related to this testing method

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

60.60 Standard published

TC 20

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

99.60 Withdrawal effective

TC 20

Amendment 1 - Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

99.60 Withdrawal effective

TC 20

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)

99.60 Withdrawal effective

TC 20

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) - Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)

60.60 Standard published

TC 20

Electric cables - Electrical tests, Partial discharge tests

Electrical material, cables, conductors and electrical equipment - Electric cables - Electrical tests, Partial discharge tests - EN 60885-2; IEC 60885-2

Standards related to this testing method

Electrical test methods for electric cables - Part 2: Partial discharge tests

99.60 Withdrawal effective

CLC/TC 20

Electrical test methods for electric cables. Part 2: Partial discharge tests

95.99 Withdrawal of Standard

TC 20

Electric cables - Additional methods

Electrical material, cables, conductors and electrical equipment - Electric cables - Additional methods - HD 605; UNE 211605

Standards related to this testing method

Electric cables - Additional test methods

99.60 Withdrawal effective

CLC/TC 20

Electric cables - Industrial cables of rated voltage 0,6/1 kV. Part 1: PVC insulated and sheathed cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Industrial cables of rated voltage 0,6/1 kV. Part 1: PVC insulated and sheathed cables - Particular requirements - UNE 21123-1

Electric cables - Electrical cables for industrial use of voltage 0,6/1kV. Part 2: XLPE insulated and PVC Sheathed cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Electrical cables for industrial use of voltage 0,6/1kV. Part 2: XLPE insulated and PVC Sheathed cables - Particular requirements - UNE 21123-2; IEC 60502-1

Standards related to this testing method

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

60.60 Standard published

TC 20

Electric cables - Electrical cables for industrial use of voltage 0,6/1kV Part 3: EPR insulated and PVC sheated cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Electrical cables for industrial use of voltage 0,6/1kV Part 3: EPR insulated and PVC sheated cables - Particular requirements; UNE 21123-3

Electric cables - Electrical cables for industrial use of voltage 0,6/1 kV Part 4: XLPE insulated and polyolefin sheathed cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Electrical cables for industrial use of voltage 0,6/1 kV Part 4: XLPE insulated and polyolefin sheathed cables - Particular requirements - UNE 21123-4; IEC 60502-1

Standards related to this testing method

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

60.60 Standard published

TC 20

Electric cables - Electrical cables for industrial use of voltage 0,6/1 kV Part 5: EPR insulated and polyolefin sheathed cables - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Electrical cables for industrial use of voltage 0,6/1 kV Part 5: EPR insulated and polyolefin sheathed cables - Particular requirements - UNE 21123-5

Electric cables - Distribution cables of rated voltage 0,6/1 kV - General requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Distribution cables of rated voltage 0,6/1 kV - General requirements - HD 603-1

Electric cables - Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section N: PVC sheathed cables without concentric conductor (Type 5N) - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section N: PVC sheathed cables without concentric conductor (Type 5N) - Particular requirements - HD 603-5N

Electric cables - Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section X: Polyolefin sheathed cables without concentric conductor (Type 5X-1) - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section X: Polyolefin sheathed cables without concentric conductor (Type 5X-1) - Particular requirements - HD 603-5X

Electric cables - Cables with intrinsic resistance to fire and intended for use in emergency circuits - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Cables with intrinsic resistance to fire and intended for use in emergency circuits - Particular requirements - UNE 211025

Electric cables - Cables of rated voltages up to and including 450/750 V and having low emission smoke and corrosive thermoplastic insulation compound - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Cables of rated voltages up to and including 450/750 V and having low emission smoke and corrosive thermoplastic insulation compound - Particular requirements - UNE 211002

Electric cables - Cables for signs and luminous- discharge-tube installations - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Cables for signs and luminous- discharge-tube installations - Particular requirements - EN 50143

Standards related to this testing method

Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V

90.93 Standard confirmed

CLC/TC 20

Electric cables - Bundle assembled cores of rated voltage 0,6/1 kV for overhead distribution, service and similar uses - Index

Electrical material, cables, conductors and electrical equipment - Electric cables - Bundle assembled cores of rated voltage 0,6/1 kV for overhead distribution, service and similar uses - Index - UNE 21030-0

Electric cables - Bundle assembled cores of rated voltage 0,6/1 kV for overhead distribution, service and similar uses - Aluminum conductors - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Bundle assembled cores of rated voltage 0,6/1 kV for overhead distribution, service and similar uses - Aluminum conductors - Particular requirements - UNE 21030-1

Electric cables - Bundle assembled cores of rated voltage 0,6/1 kV for overhead distribution, service and similar uses - Copper conductors - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Bundle assembled cores of rated voltage 0,6/1 kV for overhead distribution, service and similar uses - Copper conductors - Particular requirements - UNE 21030-2

Electric cables - Cables for earthing and short- circuiting equipment - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Cables for earthing and short- circuiting equipment - Particular requirements - EN 61138 - IEC 61138

Standards related to this testing method

Cables for portable earthing and short-circuiting equipment

60.60 Standard published

CLC/TC 20

Cables for portable earthing and short-circuiting equipment

60.60 Standard published

TC 20

Electric cables - Insulated cables with PVC for audio equipment - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Insulated cables with PVC for audio equipment - Particular requirements - UNE 211030

Electric cables - Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV - Particular requirements - HD 620-1

Electric cables - Distribution cables with extruded insulation and aluminium tape screen for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Distribution cables with extruded insulation and aluminium tape screen for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV - Particular requirements - UNE 211620

Electric cables - Single-core cables and joined single- core cables, with crosslilnked insulation of HEPR. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5) - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Single-core cables and joined single- core cables, with crosslilnked insulation of HEPR. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5) - Particular requirements - HD 620-9E

Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV - HPTR insulated single core cables and single core pre-assembled cables - Cables with polyolefine compound sheath (type 1, type 2 and type 3)

Electrical material, cables, conductors and electrical equipment - Electric cables - Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV - HPTR insulated single core cables and single core pre-assembled cables - Cables with polyolefine compound sheath (type 1, type 2 and type 3) - Particular requirements - Especificación UNE 0052

Electric cables - XLPE Insulated Single-core and 3 core cables, and single core pre- assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E- 5) - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - XLPE Insulated Single-core and 3 core cables, and single core pre- assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E- 5) - Particular requirements - HD 620-10E

Electric cables - Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV - HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, 2 and 3)

Electrical material, cables, conductors and electrical equipment - Electric cables - Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV - HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3) - Particular requirements - Especificación UNE 0051

Electric cables - Tests on extruded oversheaths with a special protective function - Dielectric test on extruded oversheaths

Electrical material, cables, conductors and electrical equipment - Electric cables - Tests on extruded oversheaths with a special protective function - Dielectric test on extruded oversheaths - EN 60229; IEC 60229

Standards related to this testing method

Electric cables - Tests on extruded oversheaths with a special protective function

60.60 Standard published

CLC/TC 20

Electric cables - Tests on extruded oversheaths with a special protective function

60.60 Standard published

TC 20

Electric cables - Hard copper plain stranded conductors for overhead electrical lines - Particular requirements - UNE 207015

Electrical material, cables, conductors and electrical equipment - Electric cables - Hard copper plain stranded conductors for overhead electrical lines - Particular requirements - UNE 207015

Electric cables - Conductors for overhead lines. Round wire concentric lay stranded conductors - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Conductors for overhead lines. Round wire concentric lay stranded conductors - Particular requirements - EN 50182

Standards related to this testing method

Conductors for overhead lines - Round wire concentric lay stranded conductors

60.60 Standard published

CLC/TC 7X

Conductors for overhead lines - Round wire concentric lay stranded conductors

60.60 Standard published

CLC/TC 7X

Conductors for overhead lines - Round wire concentric lay stranded conductors

90.93 Standard confirmed

CLC/TC 7X

Conductors for overhead lines - Round wire concentric lay stranded conductors

60.60 Standard published

CLC/TC 7X

Electric cables - Conductors for overhead lines - Aluminium-magnesium-silicon alloy wires - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Conductors for overhead lines - Aluminium-magnesium-silicon alloy wires - Particular requirements - EN 50183

Standards related to this testing method

Conductors for overhead lines - Aluminium-magnesium-silicon alloy wires

99.60 Withdrawal effective

CLC/TC 7X

Electric cables - Conductors for overhead lines - Zinc coated steel wires - Particular requirements - EN 50189

Electrical material, cables, conductors and electrical equipment - Electric cables - Conductors for overhead lines - Zinc coated steel wires - Particular requirements - EN 50189

Standards related to this testing method

Conductors for overhead lines - Zinc coated steel wires

99.60 Withdrawal effective

CLC/TC 7X

Electric cables - Hard-drawn aluminium wire for overhead line conductors - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Hard-drawn aluminium wire for overhead line conductors - Particular requirements - EN 60889; IEC 60889

Standards related to this testing method

Hard-drawn aluminium wire for overhead line conductors

99.60 Withdrawal effective

CLC/TC 7X

Hard-drawn aluminium wire for overhead line conductors

99.60 Withdrawal effective

TC 7

Electric cables - Aluminium-clad steel wires for electrical purposes - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Aluminium-clad steel wires for electrical purposes - Particular requirements - EN 61232; IEC 61232

Standards related to this testing method

Aluminium-clad steel wires for electrical purposes

60.60 Standard published

CLC/TC 7X

Aluminium-clad steel wires for electrical purposes

60.60 Standard published

CLC/TC 7X

Aluminium-clad steel wires for electrical purposes

99.60 Withdrawal effective

CLC/TC 7X

Aluminium-clad steel wires for electrical purposes

99.60 Withdrawal effective

TC 7

Electric cables - Steel wire and wire products - Non- ferrous metallic coatings on steel wire - Part 2: Zinc or zinc alloy coatings - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Steel wire and wire products - Non- ferrous metallic coatings on steel wire - Part 2: Zinc or zinc alloy coatings - Particular requirements - EN 10244-2

Standards related to this testing method

Steel wire and wire products - Non-ferrous metallic coatings on steel wire - Part 2: Zinc or zinc alloy coatings

99.60 Withdrawal effective

CEN/TC 459/SC 6

Electric cables - Electric cables for photovoltaic systems - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Electric cables for photovoltaic systems - Particular requirements - EN 50618

Standards related to this testing method

Electric cables for photovoltaic systems

90.93 Standard confirmed

CLC/TC 20

Electric cables - Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC - Particular requirements - IEC 62930

Standards related to this testing method

Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC

60.60 Standard published

TC 20

Electric cables - Communication cables - Test methods for UV resistance evaluation of the sheath of electrical and optical fibre cable

Electrical material, cables, conductors and electrical equipment - Electric cables - Communication cables - Test methods for UV resistance evaluation of the sheath of electrical and optical fibre cable - EN 50289-4-17

Standards related to this testing method

Communication cables - Specifications for test methods - Part 4-17: Test methods for UV resistance evaluation of the sheath of electrical and optical fibre cable

90.93 Standard confirmed

CLC/TC 46X

Electric cables - Charging cables for electric vehicles - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Charging cables for electric vehicles - Particular requirements - EN 50620

Standards related to this testing method

Electric cables - Charging cables for electric vehicles

90.93 Standard confirmed

CLC/TC 20

Electric cables - Charging cables for electric vehicles

60.60 Standard published

CLC/TC 20

Electric cables - Charging cables for electric vehicles for rated voltages up to and including 0,6 / 1 kV - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Charging cables for electric vehicles for rated voltages up to and including 0,6 / 1 kV - Particular requirements - IEC 62893-1; IEC 62893-2

Standards related to this testing method

Amendment 1 - Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 1: General requirements

60.60 Standard published

TC 20

Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 1: General requirements

60.60 Standard published

TC 20

Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 2: Test methods

60.60 Standard published

TC 20

Electric cables - Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV. Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV. Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V - Particular requirements - IEC 62893-3

Standards related to this testing method

Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 3: Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V

60.60 Standard published

TC 20

Electric cables - Charging cables for electric vehicles of rated voltages up to and including 0,6/1 kV. Cables for DC charging according to mode 4 of IEC 61851-1 - DC charging without use of a thermal management system - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Charging cables for electric vehicles of rated voltages up to and including 0,6/1 kV. Cables for DC charging according to mode 4 of IEC 61851-1 - DC charging without use of a thermal management system - Particular requirements - IEC 62893-4-1

Standards related to this testing method

Charging cables for electric vehicles of rated voltages up to and including 0,6/1 kV - Part 4-1: Cables for DC charging according to mode 4 of IEC 61851-1 - DC charging without use of a thermal management system

60.60 Standard published

TC 20

Electric cables - Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Particular requirements - IEC 62821-1; IEC 62821-2

Standards related to this testing method

Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements

60.60 Standard published

TC 20

Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 2: Test methods

99.60 Withdrawal effective

TC 20

Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords) - Particular requirements

Electrical material, cables, conductors and electrical equipment - Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords) - Particular requirements - IEC 62821-3

Standards related to this testing method

Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords)

60.60 Standard published

TC 20

Plugs and sockets-outlets - Non-removable plugs for type II equipment - Type test

Electrical material, cables, conductors and electrical equipment - Plugs and sockets-outlets - Not removable plugs for type II equipment - Type test

Standards related to this testing method

Flat non-rewirable two-pole plugs, 2,5 A 250 V, with cord, for the connection of class II-equipment for household and similar purposes

90.92 Standard to be revised

CLC/SR 23

Plugs and sockets-outlets for household and similar purposes - Type tests - UNE 20315

Plugs and sockets-outlets for household and similar purposes - Type tests - UNE 20315-1-1; UNE 20315-1-2; IEC 60884-1:2002; IEC 60884-1:2002/A1:2006

Standards related to this testing method

Amendment 1 - Plugs and socket-outlets for household and similar purposes - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23B

Plugs and socket-outlets for household and similar purposes - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23B

Amendment 2 - Plugs and socket-outlets for household and similar purposes - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23B

Plugs and socket-outlets for household and similar purposes - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23B

Plugs and sockets-outlets for household and similar purposes: adaptors for permanent use - Type test (except tests of electromagnetic compatibility) - UNE 20315-2-5

Plugs and sockets-outlets for household and similar purposes: adaptors for permanent use - Type test (except tests of electromagnetic compatibility) - UNE 20315-2-5

Plugs and sockets-outlets for household and similar purposes: cord extension sets - Tests type (except tests of electromagnetic compatibility)- UNE 20315-2-7

Plugs and sockets-outlets for household and similar purposes: cord extension sets - Tests type (except tests of electromagnetic compatibility)- UNE 20315-2-7

Switches for household fixed - electrical installations - type tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Switches for household fixed - electrical installations - type tests (except tests of electromagnetic compatibility) - EN 60669-1; IEC 60669-1

Standards related to this testing method

Switches for household and similar fixed-electrical installations - Part 1: General requirements

99.60 Withdrawal effective

CLC/TC 23BX

Switches for household and similar fixed-electrical installations - Part 1: General requirements

99.60 Withdrawal effective

CLC/TC 23BX

Switches for household and similar fixed-electrical installations - Part 1: General requirements

99.60 Withdrawal effective

CLC/TC 23BX

Switches for household and similar fixed-electrical installations - Part 1: General requirements

99.60 Withdrawal effective

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 1: General requirements

60.60 Standard published

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 1: General requirements

60.60 Standard published

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 1: General requirements

60.60 Standard published

CLC/TC 23BX

Corrigendum 1 - Switches for household and similar fixed-electrical installations - Part 1: General requirements

60.60 Standard published

TC 23/SC 23B

Switches for household and similar fixed-electrical installations - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23B

Switches for household and similar fixed-electrical installations - Part 1: General requirements

60.60 Standard published

TC 23/SC 23B

Switches for household fixed- electrical installations - Type Tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Switches for household fixed- electrical installations - Type Tests (except tests of electromagnetic compatibility) - EN 60669-2-1:2005; EN 60669-2-1:2005 ERRATUM 2008; EN 60669-2-1:2005/A1:2010; EN-60669-2-1:2005/A12:2011 Except Section 26

Standards related to this testing method

Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches

60.60 Standard published

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches

60.60 Standard published

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches

60.60 Standard published

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches

60.60 Standard published

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches

50.97 End of interruption of work - split/merged

CLC/TC 23BX

Electromagnetic remote-control switches for household fixed- electrical installations - Special tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Electromagnetic remote-control switches for household fixed- electrical installations - Special tests (except tests of electromagnetic compatibility) - EN 60669-2-2; IEC 60669-2-2:2006 Except Section 26

Standards related to this testing method

Switches for household and similar fixed electrical installations - Part 2-2: Particular requirements - Electromagnetic remote-control switches (RCS)

60.60 Standard published

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 2-2: Particular requirements - Electromagnetic remote-control switches (RCS)

99.60 Withdrawal effective

TC 23/SC 23B

Time delay switches for household fixed-electrical installations - Special tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Time delay switches for household fixed-electrical installations - Special tests (except tests of electromagnetic compatibility) - EN 60669-2-3; IEC 60669-2-3:2006 Except Section 26

Standards related to this testing method

Switches for household and similar fixed electrical installations - Part 2-3: Particular requirements - Time delay switches (TDS)

60.60 Standard published

CLC/TC 23BX

Switches for household and similar fixed electrical installations - Part 2-3: Particular requirements - Time-delay switches (TDS)

99.60 Withdrawal effective

TC 23/SC 23B

Switches for household and similar fixed electrical installations - Switches and related accessories for use in home and building electronic systems (HBES) - Type Tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Switches for household and similar fixed electrical installations - Switches and related accessories for use in home and building electronic systems (HBES) - Type Tests (except tests of electromagnetic compatibility); EN 60669-2-5

Standards related to this testing method

Switches for household and similar fixed electrical installations - Part 2-5: Particular requirements - Switches and related accessories for use in home and building electronic systems (HBES)

60.60 Standard published

CLC/TC 23BX

Enclosures and compartments of enclosures for the installation of Power Control Switchs - type tests (except tests for electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Enclosures and compartments of enclosures for the installation of Power Control Switchs - type tests (except tests for electromagnetic compatibility) - UNE 201003

Miniature circuit-breakers for power control, of 1,5 A to 63 A - type test (except tests of electromagnetic compatibility) - UNE 20317

Electrical material, cables, conductors and electrical equipment - Miniature circuit-breakers for power control, of 1,5 A to 63 A - type test (except tests of electromagnetic compatibility) - UNE 20317

Circuit breakers for overcurrent protection for household and similar installations (lcn<12Ka) - Type Tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Circuit breakers for overcurrent protection for household and similar installations (lcn<12Ka) - Type Tests (except tests of electromagnetic compatibility) - EN 60898-1; EN 60898-2

Standards related to this testing method

Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation

99.60 Withdrawal effective

CLC/TC 23E

Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation

99.60 Withdrawal effective

CLC/TC 23E

Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation

99.60 Withdrawal effective

CLC/TC 23E

Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation

99.60 Withdrawal effective

CLC/TC 23E

Electrical accessories - Circuit breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation

99.60 Withdrawal effective

CLC/TC 23E

Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation

99.60 Withdrawal effective

CLC/TC 23E

Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation

60.60 Standard published

CLC/TC 23E

Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation

60.60 Standard published

CLC/TC 23E

Low voltage electrical material - Environmental test (cyclic test of wet heat)

Electrical material, cables, conductors and electrical equipment - Low voltage electrical material - Environmental test (cyclic test of wet heat) - EN 60068-2-30; IEC 60068-2-30

Standards related to this testing method

Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

60.60 Standard published

CLC/SR 104

Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

60.60 Standard published

TC 104

Low voltage electrical material - Environmental testing (Test Cab: Damp heat, steady state)

Electrical material, cables, conductors and electrical equipment - Low voltage electrical material - Environmental testing (Test Cab: Damp heat, steady state) - EN 60068-2-78; IEC 60068-2-78

Standards related to this testing method

Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state

60.60 Standard published

CLC/SR 104

Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state

60.60 Standard published

TC 104

Cable accessories - Test of clamping

Electrical material, cables, conductors and electrical equipment - Cable accessories - Test of clamping - EN 50483-1; EN 50483-4

Standards related to this testing method

Test requirements for low voltage aerial bundled cable accessories - Part 1: Generalities

90.93 Standard confirmed

CLC/TC 20

Test requirements for low voltage aerial bundled cable accessories - Part 4: Connectors

90.93 Standard confirmed

CLC/TC 20

Electrotechnical products - Glowing/hot-wire based test methods - Generalities

Electrical material, cables, conductors and electrical equipment - Electrotechnical products - Glowing/hot-wire based test methods - Generalities - EN 60695-2-10; IEC 60695-2-10

Standards related to this testing method

Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure

99.60 Withdrawal effective

CLC/SR 89

Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure

60.60 Standard published

CLC/SR 89

Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure

60.60 Standard published

TC 89

Electrotechnical products - Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)

Electrical material, cables, conductors and electrical equipment - Electrotechnical products - Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) - EN 60695-2-11 IEC 60695-2-11

Standards related to this testing method

Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014)

99.60 Withdrawal effective

CLC/SR 89

Electrotechnical products - Glow-wire flammability index (GWFI) test method for materials

Electrical material, cables, conductors and electrical equipment - Electrotechnical products - Glow-wire flammability index (GWFI) test method for materials - EN 60695-2-12; IEC 60695-2-12

Standards related to this testing method

Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability index (GWFI) test method for materials

99.60 Withdrawal effective

CLC/SR 89

Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability index (GWFI) test method for materials

99.60 Withdrawal effective

CLC/SR 89

Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability index (GWFI) test method for materials

60.60 Standard published

CLC/SR 89

Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability index (GWFI) test method for materials

60.60 Standard published

TC 89

Electrotechnical products - Glow-wire ignition temperature (GWIT) test method for materials

Electrical material, cables, conductors and electrical equipment - Electrotechnical products - Glow-wire ignition temperature (GWIT) test method for materials - EN 60695-2-13; IEC 60695-2-13

Standards related to this testing method

Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials

99.60 Withdrawal effective

CLC/SR 89

Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials

99.60 Withdrawal effective

CLC/SR 89

Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials

60.60 Standard published

CLC/SR 89

Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials

60.60 Standard published

TC 89

Electrotechnical products - Needle-flame test method

Electrical material, cables, conductors and electrical equipment - Electrotechnical products - Needle-flame test method - EN 60695-11-5; IEC 60695-11-5

Standards related to this testing method

Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance

60.60 Standard published

CLC/SR 89

Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance

60.60 Standard published

TC 89

Electrical accessories - Cord sets and interconnection cord sets - Type test (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Electrical accessories - Cord sets and interconnection cord sets - Type test (except tests of electromagnetic compatibility) - EN 60799; IEC 60799

Standards related to this testing method

Electrical accessories - Cord sets and interconnection cord sets

99.60 Withdrawal effective

CLC/SR 23G

Electrical accessories - Cord sets and interconnection cord sets

60.60 Standard published

CLC/SR 23G

Electrical accessories - Cord sets and interconnection cord sets

60.60 Standard published

TC 23/SC 23G

Enclosures - Degrees of protection (code IP) - Except dust test ≥IPX7

Electrical material, cables, conductors and electrical equipment - Enclosures - Degrees of protection (code IP) - Except dust test ≥IPX7 - EN 60529; IEC 60529

Standards related to this testing method

Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

CLC/SR 70

Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

CLC/SR 70

Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

CLC/SR 70

Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

CLC/SR 70

Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

CLC/SR 70

Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

CLC/SR 70

Corrigendum 1 - Amendment 2 - Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

TC 70

Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

TC 70

Corrigendum 1 - Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

TC 70

Amendment 2 - Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

TC 70

Corrigendum 2 - Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

TC 70

Corrigendum 3 - Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

TC 70

Degrees of protection provided by enclosures (IP Code)

60.60 Standard published

TC 70

Enclosures - Degrees of protection (code IK)

Electrical material, cables, conductors and electrical equipment - Enclosures - Degrees of protection (code IK) - EN 50102; EN 62262; IEC 62262

Standards related to this testing method

Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

99.60 Withdrawal effective

CLC/SR 70

Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

99.60 Withdrawal effective

CLC/SR 70

Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

99.60 Withdrawal effective

CLC/SR 70

Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

99.60 Withdrawal effective

CLC/SR 70

Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

60.60 Standard published

CLC/SR 70

Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

60.60 Standard published

CLC/SR 70

Amendment 1 - Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

60.60 Standard published

TC 70

Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

60.60 Standard published

TC 70

Edison screw lampholders Except lampholders designed with ball screw for shade holder ring - Type tests

Electrical material, cables, conductors and electrical equipment - Edison screw lampholders Except lampholders designed with ball screw for shade holder ring - Type tests - EN 60238

Standards related to this testing method

Edison screw lampholders

60.60 Standard published

CLC/TC 34

Edison screw lampholders

60.60 Standard published

CLC/TC 34

Edison screw lampholders

60.60 Standard published

CLC/TC 34

Edison screw lampholders

99.60 Withdrawal effective

CLC/TC 34

Terminal blocks - Type test (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Terminal blocks - Type test (except tests of electromagnetic compatibility) - EN 60947-1; EN 60947-1/A1; EN 60947-1/A2; IEC 60947-1:2007; IEC 60947-1:2007/AMD1:2010; IEC 60947-1:2007/AMD2:2014; EN 60947-7-1; IEC 60947-7-1:2009; EN 60947-7-2; IEC 60947-7-2:2009

Standards related to this testing method

Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors

60.60 Standard published

CLC/TC 121A

Low-voltage switchgear and controlgear - Part 1: General rules

99.60 Withdrawal effective

CLC/TC 121A

Low-voltage switchgear and controlgear - Part 1: General rules

99.60 Withdrawal effective

CLC/TC 121A

Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors

60.60 Standard published

CLC/TC 121A

Low-voltage switchgear and controlgear - Part 1: General rules

99.60 Withdrawal effective

CLC/TC 121A

Low-voltage switchgear and controlgear - Part 1: General rules

99.60 Withdrawal effective

TC 121/SC 121A

Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors

60.60 Standard published

TC 121/SC 121A

Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors

60.60 Standard published

TC 121/SC 121A

Amendment 1 - Low-voltage switchgear and controlgear - Part 1: General rules

99.60 Withdrawal effective

TC 121/SC 121A

Low-voltage switchgear and controlgear - Part 1: General rules

99.60 Withdrawal effective

TC 121/SC 121A

Amendment 2 - Low-voltage switchgear and controlgear - Part 1: General rules

99.60 Withdrawal effective

TC 121/SC 121A

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - General Type test (except electromagnetic compatibility tests)

Electrical material, cables, conductors and electrical equipment - Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - General Type test (except electromagnetic compatibility tests) - EN 61008-1

Standards related to this testing method

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (rccb's): To rccb's functionally independent of line voltage - Special tests

Electrical material, cables, conductors and electrical equipment - Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (rccb's): To rccb's functionally independent of line voltage - Special tests - EN 61008-2-1; IEC 61008-2-1

Standards related to this testing method

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage

99.60 Withdrawal effective

TC 23/SC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - General type tests (except electromagnetic compatibility tests)

Electrical material, cables, conductors and electrical equipment - Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - General type tests (except electromagnetic compatibility tests) - EN 61009-1

Standards related to this testing method

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (rcbo's) - Special tests

Electrical material, cables, conductors and electrical equipment - Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (rcbo's) - Special tests - EN 61009-2-1; IEC 61009-2-1

Standards related to this testing method

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage

60.60 Standard published

CLC/TC 23E

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage

99.60 Withdrawal effective

TC 23/SC 23E

Low-voltage fuses - General type test (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Low-voltage fuses - General type test (except tests of electromagnetic compatibility) - EN 60269-1:2008; EN 60269-1:2008/A1:2010; IEC 60269-1:2006; IEC 60269-1:2006/AMD1:2009 Except Section 7.14

Standards related to this testing method

Low-voltage fuses - Part 1: General requirements

60.60 Standard published

CLC/SR 32B

Low-voltage fuses - Part 1: General requirements

60.60 Standard published

CLC/SR 32B

Low-voltage fuses - Part 1: General requirements

60.60 Standard published

CLC/SR 32B

Low-voltage fuses: fuses for use by unskilled persons (fuses mainly for household and similar applications) - Special tests

Electrical material, cables, conductors and electrical equipment - Low-voltage fuses: fuses for use by unskilled persons (fuses mainly for household and similar applications) - Special tests - EN 60269-3 EN 60269-3:1996/A1:2004

Standards related to this testing method

Low-voltage fuses - Part 3: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications)

99.60 Withdrawal effective

CLC/SR 32B

Low-voltage fuses - Part 3: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications)

99.60 Withdrawal effective

CLC/SR 32B

Low-voltage fuses: Fuses for use by authorized persons (fuses mainly for industrial application). Basis of blade fuses-carrier - Special tests (Except value test of crest of the admissible current of a basis for sizes 2, 3 and 4)

Electrical material, cables, conductors and electrical equipment - Low-voltage fuses: Fuses for use by authorized persons (fuses mainly for industrial application). Basis of blade fuses-carrier - Special tests (Except value test of crest of the admissible current of a basis for sizes 2, 3 and 4) - EN 60269-2; EN 60269-2/A1; EN 60269-2/A2

Standards related to this testing method

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K

60.60 Standard published

CLC/SR 32B

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application)

99.60 Withdrawal effective

CLC/SR 32B

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application)

99.60 Withdrawal effective

CLC/SR 32B

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application)

99.60 Withdrawal effective

CLC/SR 32B

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to J

99.60 Withdrawal effective

CLC/SR 32B

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application)

99.60 Withdrawal effective

CLC/SR 32B

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K

60.60 Standard published

CLC/SR 32B

Switches for appliances - General type tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Switches for appliances - General type tests (except tests of electromagnetic compatibility) - EN IEC 61058-1; IEC 61058-1

Standards related to this testing method

Switches for appliances - Part 1: General requirements

99.60 Withdrawal effective

CLC/SR 23J

Switches for appliances - Part 1: General requirements

50.98 Project deleted

CLC/SR 23J

Switches for appliances - Part 1: General requirements

99.60 Withdrawal effective

CLC/SR 23J

Switches for appliances - Part 1: General requirements

60.60 Standard published

CLC/SR 23J

Switches for appliances - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23J

Switches for appliances - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23J

Corrigendum 1 - Switches for appliances - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23J

Switches for appliances - Part 1: General requirements

60.60 Standard published

TC 23/SC 23J

Amendment 1 - Switches for appliances - Part 1: General requirements

99.60 Withdrawal effective

TC 23/SC 23J

Switches for appliances Requirements for mechanical switches - General type tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Switches for appliances Requirements for mechanical switches - General type tests (except tests of electromagnetic compatibility) - EN 61058-1-1; IEC 61058-1-1

Standards related to this testing method

Switches for appliances - Part 1-1: Requirements for mechanical switches

60.60 Standard published

CLC/SR 23J

Switches for appliances - Part 1-1: Requirements for mechanical switches

60.60 Standard published

CLC/SR 23J

Switches for appliances - Part 1-1: Requirements for mechanical switches

60.60 Standard published

TC 23/SC 23J

Switches for cords - type tests

Electrical material, cables, conductors and electrical equipment - Switches for cords - type tests - EN 61058-2-1; IEC 61058-2-1

Standards related to this testing method

Switches for appliances - Part 2-1: Particular requirements for cord switches

99.60 Withdrawal effective

CLC/SR 23J

Switches for appliances - Part 2-1: Particular requirements for cord switches

60.60 Standard published

CLC/SR 23J

Switches for appliances - Part 2-1: Particular requirements for cord switches

60.60 Standard published

TC 23/SC 23J

Switches for appliances - Part 2-1: Particular requirements for cord switches

99.60 Withdrawal effective

TC 23/SC 23J

Switches for appliances Requirements for mechanical switches - Switches for appliances Requirements for electronic switches - General type tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Switches for appliances Requirements for mechanical switches - Switches for appliances Requirements for electronic switches - General type tests (except tests of electromagnetic compatibility) - EN 61058-1-2; IEC 61058-1-2

Standards related to this testing method

Switches for appliances - Part 1-2: Requirements for electronic switches

60.60 Standard published

CLC/SR 23J

Switches for appliances - Part 1-2: Requirements for electronic switches

60.60 Standard published

CLC/SR 23J

Switches for appliances - Part 1-2: Requirements for electronic switches

60.60 Standard published

TC 23/SC 23J

Conduit systems for electrical cable management - Special tests (except tests of electromagnetic compatibility)

Electrical material, cables, conductors and electrical equipment - Conduit systems for electrical cable management - Special tests (except tests of electromagnetic compatibility) - EN 61386-1:2008; EN 61386-21:2005; EN 61386-21/A11; EN 61386-22; EN 61386-22/A11; EN 61386-23; EN 61386-23/A11; EN 61386-24; IEC 61386-1:2008; IEC 61386-21:2002; IEC 61386-22:2002; IEC 61386-23:2002; IEC 61386-24:2004 Except section 15

Standards related to this testing method

Conduit systems for cable management - Part 23: Particular requirements - Flexible conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 1: General requirements

60.60 Standard published

CLC/TC 213

Conduit systems for cable management - Part 23: Particular requirements - Flexible conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 24: Particular requirements - Conduit systems buried underground

60.60 Standard published

CLC/TC 213

Conduit systems for cable management - Part 22: Particular requirements - Pliable conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 22: Particular requirements - Pliable conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 23: Particular requirements - Flexible conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 22: Particular requirements - Pliable conduit systems

99.60 Withdrawal effective

CLC/TC 213

Conduit systems for cable management - Part 24: Particular requirements - Conduit systems buried underground

60.60 Standard published

TC 23/SC 23A

Conduit systems for cable management - Part 1: General requirements

60.60 Standard published

TC 23/SC 23A

Conduit systems for cable management - Part 1: General requirements

60.60 Standard published

TC 23/SC 23A

Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems

99.60 Withdrawal effective

TC 23/SC 23A

Conduit Systems for cable management - Part 22: Particular requirements - Pliable conduit systems

99.60 Withdrawal effective

TC 23/SC 23A

Conduit systems for cable management - Part 23: Particular requirements - Flexible conduit systems

99.60 Withdrawal effective

TC 23/SC 23A

Electrical equipment (Thermal transmitter) - Electrical safety (except radiation tests, toxicity and analogue risks)

Electrical equipment (Thermal transmitter) - Electrical safety (except radiation tests, toxicity and analogue risks) - EN 60335-1; EN 60335-2-30; IEC 60335-1

Standards related to this testing method

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

99.60 Withdrawal effective

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 1: General requirements

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 1: General requirements

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 1: General requirements

60.60 Standard published

TC 61

Household and similar electrical appliances - Safety - Part 1: General requirements

99.60 Withdrawal effective

TC 61

Electrical equipment (Thermal transmitter) - Rubbing test

Electrical equipment (Thermal transmitter) - Rubbing test (Section 4.1.3.3 corresponding to 2016 version or equivalent sections in later versions) - SANS 941

Cable management - Cable tray systems and cable ladder systems - Special tests (except tests of electromagnetic compatibility and SWL)

Cable management - Cable tray systems and cable ladder systems - Special tests (except tests of electromagnetic compatibility and SWL); EN 61537; IEC 61537

Standards related to this testing method

Cable management - Cable tray systems and cable ladder systems

60.60 Standard published

CLC/TC 213

Cable management - Cable tray systems and cable ladder systems

99.60 Withdrawal effective

TC 23/SC 23A

Protective coating anti- electrocution of birds on overhead distribution lines - General tests type

Protective coating anti- electrocution of birds on overhead distribution lines - General tests type - EA 0058

Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness)

Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness); EN ISO 868

Standards related to this testing method

Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness) (ISO 868:2003)

60.60 Standard published

CEN/TC 249

Air-conditioned equipment and heat pumps air/air, water/air, air/water and water/water units - Measure of: - Cooling capacity; - Heating capacity; - Absorbed capacity; - Energy efficiency

Air-conditioned equipment and heat pumps air/air, water/air, air/water and water/water units - Measure of: - Cooling capacity; - Heating capacity; - Absorbed capacity; - Energy efficiency - EN 14511-2; EN 14511-2; EN 14511-3; EN 14511-3; EN 14511-3:2013; SANS 54511-3

Standards related to this testing method

Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 2: Test conditions

99.60 Withdrawal effective

CEN/TC 113

Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods

99.60 Withdrawal effective

CEN/TC 113

Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 2: Test conditions

99.60 Withdrawal effective

CEN/TC 113

Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 3: Test methods

99.60 Withdrawal effective

CEN/TC 113

Air-conditioned equipment and heat pumps air/air, water/air, air/water and water/water units - Measure of the seasonal energy efficiency

Air-conditioned equipment and heat pumps air/air, water/air, air/water and water/water units - Measure of the seasonal energy efficiency - EN 14825; EN 14825:2016

Standards related to this testing method

Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling - Testing and rating at part load conditions and calculation of seasonal performance

99.60 Withdrawal effective

CEN/TC 113

Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling - Testing and rating at part load conditions and calculation of seasonal performance

99.60 Withdrawal effective

CEN/TC 113

Ducted and non-ducted Air conditioners and Heat Pumps air/air | SASO 2663:2014

Ducted and non-ducted Air conditioners and Heat Pumps air/air | SASO 2663:2014 - SASO 2681; SASO 2682; ISO 5151:2010, /except section 5.2 a/to 5.5, 6.2 a/to 6.4, 7.4; ISO 5151:2017, excepto apdo./except section 5.2 a/to 5.5, 6.2 a/to 6.4, 7.4; ISO 13253:2011, excepto apdo./except section 6.2 a/to 6.4, 7.2, 7.3, 8.4; ISO 13253:2017, excepto apdo./except section 6.2 a/to 6.4, 7.2, 7.3, 8.4, 9.3.3.5; ISO 15042

Standards related to this testing method

Non-ducted air conditioners and heat pumps — Testing and rating for performance

95.99 Withdrawal of Standard

ISO/TC 86/SC 6

Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance

95.99 Withdrawal of Standard

ISO/TC 86/SC 6

Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance

90.93 Standard confirmed

ISO/TC 86/SC 6

Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance

90.93 Standard confirmed

ISO/TC 86/SC 6

Non-ducted air conditioners and heat pumps — Testing and rating for performance

90.93 Standard confirmed

ISO/TC 86/SC 6

Non-ducted air conditioners and heat pumps — Testing and rating for performance — Amendment 1

60.60 Standard published

ISO/TC 86/SC 6

Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance — Amendment 1

60.60 Standard published

ISO/TC 86/SC 6

Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance — Amendment 1

60.60 Standard published

ISO/TC 86/SC 6

Air conditioners and Heat Pumps - Air SASO 2874 - Equipment: Table 4: Air conditioners and air cooled -Table 8: All type of VRF

Air conditioners and Heat Pumps - Air SASO 2874 - Equipment: Table 4: Air conditioners and air cooled -Table 8: All type of VRF - SASO 2681; SASO 2682; ISO 5151:2010, /except section 5.2 a/to 5.5, 6.2 a/to 6.4, 7.4; ISO 5151:2017, excepto apdo./except section 5.2 a/to 5.5, 6.2 a/to 6.4, 7.4; ISO 13253:2011, excepto apdo./except section 6.2 a/to 6.4, 7.2, 7.3, 8.4; ISO 13253:2017, excepto apdo./except section 6.2 a/to 6.4, 7.2, 7.3, 8.4, 9.3.3.5; ISO 15042

Standards related to this testing method

Non-ducted air conditioners and heat pumps — Testing and rating for performance

95.99 Withdrawal of Standard

ISO/TC 86/SC 6

Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance

95.99 Withdrawal of Standard

ISO/TC 86/SC 6

Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance

90.93 Standard confirmed

ISO/TC 86/SC 6

Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance

90.93 Standard confirmed

ISO/TC 86/SC 6

Non-ducted air conditioners and heat pumps — Testing and rating for performance

90.93 Standard confirmed

ISO/TC 86/SC 6

Non-ducted air conditioners and heat pumps — Testing and rating for performance — Amendment 1

60.60 Standard published

ISO/TC 86/SC 6

Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance — Amendment 1

60.60 Standard published

ISO/TC 86/SC 6

Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance — Amendment 1

60.60 Standard published

ISO/TC 86/SC 6

Air/air and air/water Heat pumps units - Checking of functional requirements

Air/air and air/water Heat pumps units - Checking of functional requirements - EN 14511-4

Standards related to this testing method

Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 4: Operating requirements, marking and instructions

99.60 Withdrawal effective

CEN/TC 113

Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 4: Requirements

99.60 Withdrawal effective

CEN/TC 113

Air-conditioned equipments and heat pumps air/air and air/water units - Starting test at -15⁰ C

Air-conditioned equipment and heat pumps air/air and air/water units - Starting test at -15⁰ C - NF 414

Air-conditioned equipment and heat pumps air/air and air/water units - Suitability for air/water swimming pools

Air-conditioned equipment and heat pumps air/air and air/water units - Suitability for air/water swimming pools - NF 414

Air-conditioned equipment and heat pumps air/air and air/water units - After testing measurements on VRF equipment

Air-conditioned equipment and heat pumps air/air and air/water units - After testing measurements on VRF equipment - ECP-15 VRF; ECP VRF

Residential cookers fired by solid fuel - materials, design and construction characteristics

Residential cookers fired by solid fuel (except equipments with shared chimney) - Materials, design and construction characteristics. Safety tests (except safety test of natural charge section 5.4, and electrical safety tests, section 5.7) Performance tests Instructions verification - Marking verification - EN 12815

Standards related to this testing method

Residential cookers fired by solid fuel - Requirements and test methods

90.92 Standard to be revised

ТК-8

Residential cookers fired by solid fuel - Requirements and test methods

60.60 Standard published

ТК-8

Residential cookers fired by solid fuel - Requirements and test methods

95.99 Withdrawal of Standard

ТК-8

Residential independent boilers fired by solid fuel. Nominal heat output up to 50 kW (except equipment with shared chimney) - Materials, design and construction characteristics

Residential independent boilers fired by solid fuel. Nominal heat output up to 50 kW (except equipment with shared chimney) - Materials, design and construction characteristics - Safety tests - Performance tests Instruction verifications Marking verification

Standards related to this testing method

Residential independent boilers fired by solid fuel - Nominal heat output up to 50 kW - Requirements and test methods

90.92 Standard to be revised

ТК-8

Residential independent boilers fired by solid fuel - Nominal heat output up to 50 kW - Requirements and test methods

60.60 Standard published

ТК-8

Residential independent boilers fired by solid fuel - Nominal heat output up to 50 kW - Requirements and test methods

60.60 Standard published

ТК-8

Inset appliances including open fires fired by solid fuels (except equipments with shared chimney) - Materials, design and construction characteristics. Safety tests (except safety tests of natural charge, section 5.4 and electrical safety tests, section

Inset appliances including open fires fired by solid fuels (except equipments with shared chimney) - Materials, design and construction characteristics. Safety tests (except safety tests of natural charge, section 5.4 and electrical safety tests, section

Standards related to this testing method

Inset appliances including open fires fired by solid fuels - Requirements and test methods

90.92 Standard to be revised

ТК-8

Inset appliances including open fires fired by solid fuels - Requirements and test methods

60.60 Standard published

ТК-8

Inset appliances including open fires fired by solid fuels - Requirements and test methods

60.60 Standard published

ТК-8

Inset appliances including open fires fired by solid fuels - Requirements and test methods

95.99 Withdrawal of Standard

ТК-8

Roomheaters fired by solid fuel. (except equipments with shared chimney) - Materials, design and construction characteristics - Safety tests - Performance tests instruction verification and marking verification

Estufas que utilizan combustible sólido (excepto equipos con chimenea compartida) Roomheaters fired by solid fuel. (except equipments with shared chimney) Características de materiales, diseño y construcción. Ensayos de seguridad (excepto ensayo de seguridad de tiro natural apdo. 5.1 y ensayos de seguridad eléctrica, apdo. 5.7) Ensayos de prestaciones. Verificación de instrucciones. Verificación de marcado (Excepto los ensayos de caracterización de los combustibles) Materials, design and construction characteristics - Safety tests (except safety test of natural charge, section 5.1. and tests of electrical safety, section 5.7) - Performance tests Instruction verifications Marking verification; EN 13240

Standards related to this testing method

Roomheaters fired by solid fuel - Requirements and test methods - National Annex to BDS EN 13240:2006

60.60 Standard published

ТК-8

Roomheaters fired by solid fuel - Requirements and test methods

60.60 Standard published

ТК-8

Residential space heating appliances fired by wood pellets - Requirements and test methods

Residential space heating appliances fired by wood pellets - Requirements and test methods - EN 14785

Standards related to this testing method

Residential space heating appliances fired by wood pellets - Requirements and test methods

60.60 Standard published

ТК-8

Heating boilers of nominal heat output of up to 70 Kw - Requirements and test methods

Calderas de potencia nominal hasta 70 Kw Heating boilers of nominal heat output of up to 70 Kw Requisitos y métodos de ensayo (excepto ensayos de seguridad eléctrica y compatibilidad electromagnética) Requirements and test methods EN 303-5 EN 303-5

Standards related to this testing method

Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking

95.99 Withdrawal of Standard

ТК-8

Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking

60.60 Standard published

ТК-8

Heating equipment by solid fuel - Emissions determination: - Volatile Organics Compounds (VOCs)

Heating equipment by solid fuel - Emissions determination: - Volatile Organics Compounds (VOCs); CEN/TS 15883; CEN/TS 15883; EN 16510-1

Standards related to this testing method

Residential solid fuel burning appliances - Emission test methods

90.93 Standard confirmed

CEN/TC 295

Residential solid fuel burning appliances - Part 1: General requirements and test methods

99.60 Withdrawal effective

CEN/TC 295

Heating equipments by solid fuel - Emissions determination - Nitrogen oxides

Heating equipments by solid fuel - Emissions determination - Nitrogen oxides - CEN/TS 15883; CEN/TS 15883; EN 16510-1

Standards related to this testing method

Residential solid fuel burning appliances - Emission test methods

90.93 Standard confirmed

CEN/TC 295

Residential solid fuel burning appliances - Part 1: General requirements and test methods

99.60 Withdrawal effective

CEN/TC 295

Heating equipments by solid fuel - Emissions determination - Particulates (gravimetric method)

Heating equipments by solid fuel - Emissions determination - Particulates (gravimetric method) - CEN/TS 15883; CEN/TS 15883; EN 16510-1

Standards related to this testing method

Residential solid fuel burning appliances - Emission test methods

90.93 Standard confirmed

CEN/TC 295

Residential solid fuel burning appliances - Part 1: General requirements and test methods

99.60 Withdrawal effective

CEN/TC 295

Heating equipments by solid fuel - Electrical consumption determination

Heating equipments by solid fuel - Electrical consumption determination - EN 15456

Standards related to this testing method

Heating boilers - Electrical power consumption for heat generators - System boundaries - Measurements

90.60 Close of review

CEN/TC 57

Heat pumps with electrically driven compressors - Performance and determination of energy consumption in DHW production

Heat pumps with electrically driven compressors - Performance and determination of energy consumption in DHW production - EN 16147

Standards related to this testing method

Heat pumps with electrically driven compressors - Testing, performance rating and requirements for marking of domestic hot water units

95.99 Withdrawal of Standard

ТК-41

Heat pumps with electrically driven compressors - Testing, performance rating and requirements for marking of domestic hot water units

95.99 Withdrawal of Standard

ТК-41

Heat pumps with electrically driven compressors -

Heat pumps with electrically driven compressors - Construction and Performance Tests - EN 16147:2017

Standards related to this testing method

Heat pumps with electrically driven compressors - Testing, performance rating and requirements for marking of domestic hot water units

99.60 Withdrawal effective

CEN/TC 113

Heat pumps with electrically driven compressors - Testing, performance rating and requirements for marking of domestic hot water units

99.60 Withdrawal effective

CEN/TC 113

Metallic materials - Tensile testing

Metallic materials - Tensile testing (F ≤ 600kN) - EN ISO 6892-1

Standards related to this testing method

Metallic materials - Tensile testing - Part 1: Method of test at room temperature (ISO 6892-1:2019)

60.60 Standard published

CEN/TC 459/SC 1

Copper Tubes and copper accessories - Diameter determination ( 300 mm) and thickness ( 25 mm)

Copper Tubes and copper accessories - Diameter determination ( 300 mm) and thickness ( 25 mm) - Internal procedure PE-TUC 04

Copper Tubes and copper accessories - Hydrostatic pressure (P ≤ 100 bar)

Copper Tubes and copper accessories - Hydrostatic pressure (P ≤ 100 bar) - EN 1057

Standards related to this testing method

Copper and copper alloys - Seamless, round copper tubes for water and gas in sanitary and heating applications

90.93 Standard confirmed

CEN/TC 133

Copper Tubes and copper accessories - Bend

Copper Tubes and copper accessories - Bend - EN ISO 8491

Standards related to this testing method

Metallic materials - Tube (in full section) - Bend test (ISO 8491:1998)

90.93 Standard confirmed

CEN/TC 459/SC 10

Copper Tubes and copper accessories - Drift-expanding at 45°

Copper Tubes and copper accessories - Drift-expanding at 45° - EN ISO 8493

Standards related to this testing method

Metallic materials - Tube - Drift-expanding test (ISO 8493:1998)

90.93 Standard confirmed

CEN/TC 459/SC 10

Copper Tubes and copper accessories - Flanging

Copper Tubes and copper accessories - Flanging - EN ISO 8494

Standards related to this testing method

Metallic materials - Tube - Flanging test (ISO 8494:2013)

60.60 Standard published

CEN/TC 459/SC 10

Copper Tubes and copper accessories - Marking, aspect and weight of soft welding metals verification

Copper Tubes and copper accessories - Marking, aspect and weight of soft welding metals verification - Internal procedure - PE-TUC 30

Flexible hose - Tightening; Bending test; Thermal ageing method; Tensile testing; Hydrostatic pressure; Resistance to cycles of pressure; Resistance to the impulses of pressure; Bending test; Test of resistance to the freezing

Flexible hose - Tightening; Bending test; Thermal ageing method; Tensile testing; Hydrostatic pressure; Resistance to cycles of pressure; Resistance to the impulses of pressure; Bending test; Test of resistance to the freezing

Standards related to this testing method

Flexible hose assemblies in drinking water installations - Functional requirements and test methods

90.92 Standard to be revised

CEN/TC 164

Metallic security barriers - Surface aspect + Thikness and dimensions

Metallic security barriers - Surface aspect - Thikness and dimensions - UNE 135121

Iron and steel products - Measurement of coating thickness magnetic method. Thickness ( 1mm)

Iron and steel products - Measurement of coating thickness magnetic method. Thickness ( 1mm) - EN ISO 2178

Standards related to this testing method

Gas turbine applications - Safety (ISO 21789:2022)

60.60 Standard published

ТК-60

Iron and steel products - Gravimetric determination of the mass per unit area

Iron and steel products - Gravimetric determination of the mass per unit area - EN ISO 1460

Standards related to this testing method

Metallic coatings - Hot dip galvanized coatings on ferrous materials - Gravimetric determination of the mass per unit area (ISO 1460:2020)

60.60 Standard published

ТК-42

Vertical signs. Fixed metallic vertical road traffic signs. Non retroreflective area - Impact resistance test

Vertical signs. Fixed metallic vertical road traffic signs. Non retroreflective area - Impact resistance test UNE 135331; EN 12899-1; EN ISO 6272-1

Standards related to this testing method

Fixed, vertical road traffic signs - Part 1: Fixed signs

90.92 Standard to be revised

ТК-68

Paints and varnishes - Rapid-deformation (impact resistance) tests - Part 1: Falling-weight test, large-area indenter (ISO 6272-1:2011)

60.60 Standard published

ТК-39

Vertical signs. Retroreflective sheetings with glass beads - Substrate Adherence

Señalización vertical. Láminas retrorreflectantes con microesferas de vidrio Vertical signs. Retroreflective sheetings with glass beads Resistencia a la caída de una masa (ensayo pasa/no pasa) Impact resistance test UNE-135334 UNE-EN ISO 6272-1 UNE-EN 12899-1 Adherencia al sustrato Substrate Adherence UNE 135334

Standards related to this testing method

Fixed, vertical road traffic signs - Part 1: Fixed signs

90.92 Standard to be revised

ТК-68

Paints and varnishes - Rapid-deformation (impact resistance) tests - Part 1: Falling-weight test, large-area indenter (ISO 6272-1:2011)

60.60 Standard published

CEN/TC 139

Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements - reaction to fire

Cables de energía, control y comunicación / Power, control and communication cables Cables para aplicaciones generales en construcciones sujetos a requisitos de reacción al fuego UNE‐EN 50575 Cables for general applications in construction works subject to reaction to fire requirements EN 50575 • Reacción al fuego • Reaction to fire

Standards related to this testing method

Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements

90.93 Standard confirmed

CLC/TC 20

Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements

60.60 Standard published

CLC/TC 20

Room heaters - Household and similar electrical appliances - Safety

Household and similar electrical appliances - Safety - Particular requirements for room heaters; EN 60335-2-30; EN IEC 60335-2-30; IEC 60335-2-30

Standards related to this testing method

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

CLC/TC 61

Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

99.60 Withdrawal effective

TC 61

Amendment 2 - Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

99.60 Withdrawal effective

TC 61

Household and similar electrical appliances - Safety -Part 2-30: Particular requirements for room heaters

60.60 Standard published

TC 61

Amendment 1 - Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

TC 61

Corrigendum 1 - Household and similar electrical appliances - Safety - Part 2-30: Particular requirements for room heaters

60.60 Standard published

TC 61