prEN ISO 29461-2

Air intake filter systems for rotary machinery - Part 2: Test methods and classification for cleanable (pulse jet) filter systems prEN ISO 29461-2

General information

30.98   Project deleted   Jun 8, 2012

CEN

CEN/TC 195 Cleaning equipment for air and other gases

European Norm

29.160.99   Other standards related to rotating machinery

Scope

This standard covers methods on how to test air filters and air filter intakes systems for rotary machinery like gas turbines, compressors and for stationary internal combustion engines. The envelope for testing is in the range of 0.25 m3/s (900 m3/h) up to 1.67 m3/s (6000 m3/h).
Parameters to be evaluated include fractional particle removal efficiency (0.3-1.2 um for fine filters and 1.0-5.5 um for coarse filters), airflow resistance (energy consumption), loading characteristics.
This international standard applies to air filters having an initial efficiency of less than 99.98% with respect to 0.4 um particles.
Part 2 of the standard refers to cleanable filter systems.

Life cycle

NOW

ABANDON
prEN ISO 29461-2
30.98 Project deleted
Jun 8, 2012




Access Genorma App Everywhere