ISO/TR 18931:2001

Imaging materials - Recommendations for humidity measurement and control ISO/TR 18931:2001

Publication date:   May 31, 2001

General information

60.60 Standard published   May 31, 2001

ISO

ISO/TC 42 Photography

Technical Report

37.040.20   Photographic paper, films and plates. Cartridges

Buying

Published

Language in which you want to receive the document.

Scope

This Technical Report discusses devices in photographic standardization that are used as hygrometers and
humidistats in the measurement and control of relative humidity (RH) in test chambers and storage areas. Special
attention is given to situations where a photographic standard specifies controlling relative humidity to _ 2 % RH or
better.
Electric hygrometers are recommended for their precision, low cost, and accuracy when properly calibrated.
Calibration can be done either by the vendor or in-house by a dew-point measurement. Where the budget permits,
dew-point combined with ambient temperature measurements (converted to relative humidity) may be the only
sensor system.

Life cycle

NOW

PUBLISHED
ISO/TR 18931:2001
60.60 Standard published
May 31, 2001