ISO/ASTM 51540:2002

Practice for use of a radiochromic liquid dosimetry system ISO/ASTM 51540:2002

Publication date:   Apr 18, 2002

95.99   Withdrawal of Standard   Jul 8, 2004

General information

95.99   Withdrawal of Standard   Jul 8, 2004

ISO/ASTM

ISO/TC 85 Nuclear energy, nuclear technologies, and radiological protection

International Standard

17.240   Radiation measurements

Buying

Withdrawn

Language in which you want to receive the document.

Scope

ISO/ASTM 51540 covers the preparation, handling, testing and procedure for using radiochromic liquid dosimetry systems of radiochromic dye solutions held in sealed or capped containers (e.g., ampoules, vials). It also covers the use of spectrophotometric or photometric read-out equipment for measuring absorbed doses in materials irradiated by photons and electrons.
This practice applies to radiochromic liquid dosimeter solutions that can be used within part or all of the specified ranges as follows:
the absorbed dose range is from 0,5 Gy to 40 000 Gy for photons and electrons;
the absorbed dose rate is from 10-3 Gy s -1to 1011 Gy s-1;
the radiation energy range for photons is from 0,01 MeV to 20 MeV;
the radiation energy range for electrons is from 0,01 MeV to 20 MeV;
the irradiation temperature range is from - 40 °C to + 60 °C.

Life cycle

PREVIOUSLY

WITHDRAWN
ISO 15565:1998

NOW

WITHDRAWN
ISO/ASTM 51540:2002
95.99 Withdrawal of Standard
Jul 8, 2004

REVISED BY

WITHDRAWN
ISO/ASTM 51540:2004




Access Genorma App Everywhere

Get fast and easy access to top European and International standards (EN, ISO, IEC) via your mobile phone, tablet or the web.