ISO/ASTM 51538:2002

Practice for use of the ethanol-chlorobenzene dosimetry system ISO/ASTM 51538:2002

Publication date:   Apr 18, 2002

95.99   Withdrawal of Standard   Jul 7, 2009

General information

95.99   Withdrawal of Standard   Jul 7, 2009

ISO/ASTM

ISO/TC 85 Nuclear energy, nuclear technologies, and radiological protection

International Standard

17.240   Radiation measurements

Buying

Withdrawn

Language in which you want to receive the document.

Scope

ISO/ASTM 51538 covers the preparation, handling, testing and procedure for using the ethanol-chlorobenzene dosimetry system to measure absorbed doses in materials irradiated by photons and electrons in terms of absorbed dose in water. The system consists of a dosimeter and appropriate analytical instrumentation. This practice describes the titration analysis as a standard readout procedure for the ECB dosimeter and applies only to gamma rays, X rays and high-energy electrons.
This practice applies provided the following are satis-fied:
the absorbed dose range is from 10 Gy to 2 MGy;
the absorbed dose rate does not exceed 106 Gy s -1;
for radionuclide gamma-ray sources, the initial photon energy is greater than 0,6 MeV;
for bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons is equal to or greater than 2 MeV;
for electron beams, the initial electron energy is equal to or greater than 4 MeV.
the irradiation temperature of the dosimeter is within the range from - 40 °C to 80°C;
the effects of size and shape of the irradiation vessel on the response of the dosimeter can adequately be taken into account by performing the appropriate calculations using cavity theory.

Life cycle

PREVIOUSLY

WITHDRAWN
ISO 15563:1998

NOW

WITHDRAWN
ISO/ASTM 51538:2002
95.99 Withdrawal of Standard
Jul 7, 2009

REVISED BY

WITHDRAWN
ISO/ASTM 51538:2009