ISO 15758:2004

Hygrothermal performance of building equipment and industrial installations — Calculation of water vapour diffusion — Cold pipe insulation systems ISO 15758:2004

Publication date:   Sep 30, 2004

95.99 Withdrawal of Standard   May 5, 2014

General information

95.99 Withdrawal of Standard   May 5, 2014

ISO

ISO/TC 163/SC 2 Calculation methods

International Standard

91.120.10   Thermal insulation of buildings | 91.140.01   Installations in buildings in general

Buying

Withdrawn

Language in which you want to receive the document.

Scope

ISO 15758:2004 specifies a method to calculate the density of water vapour flow rate in cold pipe insulation systems, and the total amount of water diffused into the insulation over time. This calculation method presupposes that water vapour can only migrate into the insulation system by diffusion, with no contribution from airflow. It also assumes the use of homogeneous, isotropic insulation materials so that the water vapour partial pressure is constant at all points equidistant from the axis of the pipe.
ISO 15758:2004 is applicable when the temperature of the medium in the pipe is above 0 °C. It applies to pipes inside buildings as well as in the open air.

Life cycle

NOW

WITHDRAWN
ISO 15758:2004
95.99 Withdrawal of Standard
May 5, 2014

REVISED BY

PUBLISHED
ISO 15758:2014