ISO 10893-10:2011

Non-destructive testing of steel tubes — Part 10: Automated full peripheral ultrasonic testing of seamless and welded (except submerged arc-welded) steel tubes for the detection of longitudinal and/or transverse imperfections ISO 10893-10:2011

General information

90.60 Close of review   Mar 14, 2022

ISO

ISO/TC 17/SC 19 Technical delivery conditions for steel tubes for pressure purposes

International Standard

77.040.20   Non-destructive testing of metals | 23.040.10   Iron and steel pipes | 77.140.75   Steel pipes and tubes for specific use

Scope

ISO 10893-10:2011 specifies requirements for automated full peripheral ultrasonic shear wave (generated by conventional or phased array technique) testing of seamless and welded [except submerged arc-welded (SAW)] steel tubes, for the detection of longitudinal and/or transverse imperfections.
In the case of testing on longitudinal imperfections, Lamb wave testing can be applied at the discretion of the manufacturer.
For seamless tubes, by agreement between the purchaser and manufacturer, testing principles of ISO 10893-10:2011 can be applied to detect imperfections having other orientations.
ISO 10893-10:2011 is applicable to the inspection of tubes with an outside diameter greater than or equal to 10 mm, normally with an outside diameter-to-thickness ratio greater than or equal to 5.
It can also be applicable to the testing of circular hollow sections.

Life cycle

PREVIOUSLY

WITHDRAWN
ISO 9303:1989

WITHDRAWN
ISO 9305:1989

NOW

PUBLISHED
ISO 10893-10:2011
90.60 Close of review
Mar 14, 2022

CORRIGENDA / AMENDMENTS

PUBLISHED
ISO 10893-10:2011/Amd 1:2020