ISO 10534-2:1998

Acoustics — Determination of sound absorption coefficient and impedance in impedance tubes — Part 2: Transfer-function method ISO 10534-2:1998

Publication date:   Nov 19, 1998

95.99 Withdrawal of Standard   Oct 6, 2023

General information

95.99 Withdrawal of Standard   Oct 6, 2023

ISO

ISO/TC 43/SC 2 Building acoustics

International Standard

17.140.01   Acoustic measurements and noise abatement in general

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This test method covers the use of an impedance tube, two microphone locations and a digital frequency analysis system for the determination of the sound absorption coefficient of sound absorbers for normal sound incidence. It can also be applied for the determination of the acoustical surface impedance or surface admittance of sound absorbing materials. Since the impedance ratios of a sound absorptive material are related to its physical properties, such as airflow resistance, porosity, elasticity and density, measurements described in this test method are useful in basic research and product development.
The test method is similar to the test method specified in ISO 10534-1 in that it uses an impedance tube with a sound source connected to one end and the test sample mounted in the tube at the other end. However, the measurement technique is different. In this test method, plane waves are generated in a tube by a noise source, and the decomposition of the interference field is achieved by the measurement of acoustic pressures at two fixed locations using wall-mounted microphones or an in-tube traversing microphone, and subsequent calculation of the complex acoustic transfer function, the normal incidence absorption and the impedance ratios of the acoustic material. The test method is intended to provide an alternative, and generally much faster, measurement technique than that of ISO 10534-1.
Compared with the measurement of the sound absorption in a reverberation room according to the method specified in ISO 354, there are some characteristic differences. The reverberation room method will (under ideal conditions) determine the sound absorption coefficient for diffuse sound incidence, and the method can be used for testing of materials with pronounced structures in the lateral and normal directions. However, the reverberation room method requires test specimens which are rather large, so it is not convenient for research and development work, where only small samples of the absorber are available. The impedance tube method is limited to parametric studies at normal incidence but requires samples of the test object which are of the same size as the cross-section of the impedance tube. For materials that are locally reacting, diffuse incidence sound absorption coefficients can be estimated from measurement results obtained by the impedance tube method. For transformation of the test results from the impedance tube method (normal incidence) to diffuse sound incidence, see annex F.

Life cycle

NOW

WITHDRAWN
ISO 10534-2:1998
95.99 Withdrawal of Standard
Oct 6, 2023

REVISED BY

PUBLISHED
ISO 10534-2:2023