Superconductivity - Part 8: AC loss measurements - Total AC loss measurement of Cu/Nb-Ti composite superconducting wires exposed to a transverse alternating magnetic field by a pickup coil method IEC 61788-8:2003 ED1
17.220.20
Measurement of electrical and magnetic quantities
| 29.050
Superconductivity and conducting materials
Buying
Revised
Scope
Specifies the measurement method of total AC losses by the pickup coil method in Cu/Nb-Ti composite superconducting wires exposed to a transverse alternating magnetic field. The losses may contain both hysteresis and coupling losses. The standard method to measure only the hysteresis loss in DC or low-sweep-rate magnetic field is specified in IEC 61788-13.
Life cycle
NOW
WITHDRAWN IEC 61788-8:2003 ED1 99.60
Withdrawal effective Jun 24, 2010