30.97 End of interruption of work - split/merged Aug 21, 2020
IEC
International Standard
33.180.20 Fibre optic interconnecting devices
IEC 61300-2-48: 2009 details a procedure for determining the suitability of a fibre optic device or closure to withstand variations in humidity and temperature that may occur during operation, storage and/or transport. The test is intended to indicate the performance of such devices when exposed to heat and humidity followed by short-term freezing. In general terms, this test provides a high temperature to induce potential failures due to softening and expansion, a high humidity to encourage moisture absorption and swelling and a low temperature to facilitate ice formation, embrittlement and contraction. This test differs from other cyclic environmental tests, notably the damp heat cyclic test of IEC 61300-2-46 and the composite temperature-humidity cyclic test of 61300-2-21, by incorporating alternative levels of severity. This is achieved through
a) a greater number of cycles;
b) a greater cyclic temperature range;
c) a decreased cyclic period.
This second edition of IEC 61300-2-48 cancels and replaces the first edition published in 2003 and constitutes a technical revision. The main changes are the addition of the Category O cycle procedure and the severity reconsideration.
ABANDON
IEC 61300-2-48/FRAGF ED2
30.97
End of interruption of work - split/merged
Aug 21, 2020