IEC 60939-2:2005 applies to passive filter units for electromagnetic interference suppression which fall within the scope of the Generic Specification IEC 60939-1. The scope of this Sectional specification is restricted to passive filter units for which safety tests are appropriate. This implies that filters specified according to this Sectional specification will either be connected to mains supplies, when compliance with the mandatory tests of Table 3 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. This Sectional specification applies to passive filter units which will be connected to an a.c. mains or other supply with a nominal voltage not exceeding 1 000 V a.c., with a nominal frequency not exceeding 400 Hz, or 1 000 V d.c.
The major changes that have been made between the first and the second edition are :
– Capacitance and tan δ measurements, d.c. line resistance or voltage drop at rated current, impulse voltage, passive flammability, current overload, solvent resistance of marking, component solvent resistance and active flammability have been added to Clause 4, test and measurement procedures.
The contents of the corrigendum of November 2005 have been included in this copy.