IEC 60364-7-701:2019 ED3

Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower IEC 60364-7-701:2019 ED3

Publication date:   Oct 14, 2019

General information

60.60 Standard published   Oct 14, 2019

IEC

TC 64

International Standard

91.140.50   Electricity supply systems | 29.020   Electrical engineering in general

Buying

Published

Language in which you want to receive the document.

Scope

IEC 60364-7-701:2019 applies to electrical installations in indoor or outdoor locations where a bath tub and/or a shower is intended to be permanently placed in a specific location.
The extent of the location containing a bath tub and/or a shower is limited by:
– the lowest finished floor level;
– a horizontal plane 3 m above the lowest finished floor level;
– a vertical circumscribing virtual surface at a distance of 4 m from the fixed water outlet for the bath tub or shower; and
– the volume within the walls, floor and ceiling that border the location containing a bath or shower, measured to a depth of 6 cm.
The requirements of this document also apply to fixed electrical installations in mobile applications, for example caravans, mobile homes, shower containers. This document does not apply to emergency facilities, for example emergency showers used in industrial areas or laboratories.
This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– the scope gives precisions relevant to the application of this document;
– the description of zones is improved;
– relevant terms are defined.

Life cycle

PREVIOUSLY

WITHDRAWN
IEC 60364-7-701:2006 ED2

NOW

PUBLISHED
IEC 60364-7-701:2019 ED3
60.60 Standard published
Oct 14, 2019