IEC 60335-2-51:2002+AMD1:2008+AMD2:2011 CSV ED3.2

Household and similar electrical appliances - Safety - Part 2-51: Particular requirements for stationary circulation pumps for heating and service water installations

General information

99.60   Withdrawal effective   Apr 15, 2019

WPUB   

IEC

TC 61 Safety of household and similar electrical appliances

International Standard

23.080   Pumps | 91.140.10   Central heating systems

Scope

IEC 60335-2-51:2002+A1:2008+A2:2011 deals with the safety of electric stationary circulation pumps intended for use in heating systems or in service water systems, having a rated power input not exceeding 300 W, their rated voltage being not more than 250 V for single-phase and 480 V for other appliances. Hydraulic and electric parts of the pump may be in the same enclosure, so that the water serves as a coolant, or they maybe seperate. This standard does not apply to:
- pumps for circulating liquids other than water;
- pumps, other than circulation pumps (IEC 60335-2-41);
- circulation pumps intended exclusively for industrial purposes;
- circulation pumps intended for locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapor, or gas).

This publication is to be read in conjunction with IEC 60335-1:2010.

This consolidated version consists of the third edition (2002), its amendment 1 (2008) and its amendment 2 (2011). Therefore, no need to order amendments in addition to this publication.