IEC 60317-47:2013 ED2

Specifications for particular types of winding wires - Part 47: Aromatic polyimide enamelled rectangular copper wire, class 240 IEC 60317-47:2013 ED2

Publication date:   Jun 14, 2024

General information

60.60 Standard published   Oct 14, 2013

IEC

TC 55

International Standard

29.060.10   Wires

Buying

Published

Language in which you want to receive the document.

Scope

IEC 60317-47:2013 specifies the requirements of enamelled rectangular copper winding wire of class 240 with a sole coating of aromatic polyimide resin. The range of nominal conductor dimensions covered by this standard is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness, as well as the specified width/thickness ratio, are given in IEC 60317-0-2. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- deletion of the "in some countries" statement in the scope;
- new subclause containing general notes on winding wire, formerly a part of the scope;
- new subclause containing requirements for appearance;
- revision to the notes in Clause 19, Dielectric dissipation factor;
- new Clause 23, Pin hole test. Keywords: requirements of enamelled rectangular copper winding wire, class 240, sole coating of aromatic polyimide resin.

This publication is to be read in conjunction with IEC 60317-0-2:2013.

Life cycle

PREVIOUSLY

WITHDRAWN
IEC 60317-47:1997 ED1

NOW

PUBLISHED
IEC 60317-47:2013 ED2
60.60 Standard published
Oct 14, 2013

CORRIGENDA / AMENDMENTS

PUBLISHED
IEC 60317-47:2013/AMD1:2024 ED2