50.60 Close of voting. Proof returned by secretariat Jul 21, 2023
CENELEC
CLC/TC 66X Safety of measuring, control, and laboratory equipment
European Norm
19.080 Electrical and electronic testing
Draft
IEC 61010-2-032:2023 specifies safety requirements for hand-held and hand-manipulated current sensors intended for measuring, detecting or injecting current, or indicating current waveforms on circuits without physically opening the current path of the circuit being measured.
These current sensors are hand-manipulated before and/or after a test or measurement, but are not necessarily hand-held during the test or measurement. They can be stand-alone current sensors or accessories to other equipment or parts of combined equipment. These include measurement circuits which are part of electrical test and measurement equipment, laboratory equipment, or process control equipment.
This fifth edition cancels and replaces the fourth edition published in 2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) In 1.1.1, definitions of current sensor types have been moved to a new Annex FF;
b) Clause 2, all normative references have been dated and new normative references have been added;
c) 3.2.103, a new definition protective fingerguard has been added which replaces the previous definition of protective barrier;
d) 4.4.2.101 is a new subclause about surge protective devices;
e) in 5.1.5.101.2, minimum ratings for voltage of measuring terminals are required;
f) Subclause 6.5.1 has been modified;
g) Subclause 6.5.5 is no longer used;
h) Subclause 6.6.101 modifies 6.6.101 and 6.6.102 of previous edition:
1) in 6.6.101.1, insulating material of group I may be allowed for determination of creepage distances of measuring circuit terminals;
2) in 6.6.101.2, clearances and creepage distances up to 3 000 V for measuring circuit terminals in unmated position have been defined;
3) in 6.6.101.3, requirements for measuring circuit terminals in partially mated position have been specified;
4) in 6.6.101.4, requirements for measuring circuit terminals in mated position have been specified;
5) Subclause 6.6.101.5 replaces 6.6.102;
i) Subclause 6.6.102 replaces 6.101 of previous edition with modifications;
j) Subclause 6.101.2 replaces 6.9.101.1 of previous edition with modifications;
k) Subclause 6.101.3 replaces 6.9.101.2 of previous edition with modifications;
l) Subclause 6.101.4 replaces 6.9.102 of previous edition with modifications;
m) in 8.101, jaw ends abrasion test has been modified;
n) 8.105 is a new subclause for input/output leads attachment has been added;
o) in 9.101.2, relocation of 101.3 of previous edition;
p) in 9.101.3, relocation of 101.4 of previous edition, extension to measurement category II and reference to IEC 61000-4-5 for tests:
q) Table 104 has been replaced by Table K.101:
r) in 9.102, relocation of Clause 102 of previous edition;
s) in 14.101, relocation of 14.102. Subclause 14.101 of previous edition has been deleted;
t) 101.3 is a new subclause for protections against hazard occurring from reading a voltage value in replacement of Clause EE.5 of previous edition;
u) in Table D.101, transients are disregarded for insulation between jaw ends and input/output circuits;
v) in Clause F.101, test voltages for routine test of jaws have been modified;
w) in K.2.1, another method for determination of clearances of secondary circuits is proposed;
x) in K.3.2, new Table K.15 and Table K.16 for clearance calculatio
Legislation related to this standard
Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
PUBLISHED
EN IEC 61010-2-032:2021
IN_DEVELOPMENT
FprEN IEC 61010-2-032:2023
50.60
Close of voting. Proof returned by secretariat
Jul 21, 2023