45.99 Dispatch of FV draft to CCMC Aug 7, 2026
CEN
CEN/TC 155 Plastics piping systems and ducting systems
European Norm
23.040.01 Pipeline components and pipelines in general
Draft
This document gives the definitions and specifies the minimum requirements for injection moulded, extruded and thermoformed thermoplastics boxes, including integral components, used in underground systems for infiltration, attenuation and storage of surface water (e.g. storm water) and manufactured from polypropylene (PP) or unplasticized polyvinylchloride (PVC-U).
NOTE Non load bearing component(s) of boxes can be manufactured by various methods e.g. extrusion, injection moulding, rotational moulding, thermoforming and low-pressure injection moulding.
Product properties are determined by a combination of material specifications, design and manufacturing process.
Boxes are intended for use in landscape, pedestrian or vehicular traffic areas.
Boxes can either be factory assembled, or site assembled from different components.
Boxes are intended to be used as elements in a modular system where the manufacturer states in the documentation how the boxes are assembled to create a complete infiltration, attenuation or storage system.
PUBLISHED
EN 17152-1:2019
IN_DEVELOPMENT
FprEN 17152-1
45.99
Dispatch of FV draft to CCMC