FprCEN/TS 15502-3-2

Gas-fired central heating boilers - Part 3-2: H2NG - Expansion of EN 15502-2-2:2024

General information

30.99   CD approved for registration as DIS   Jul 31, 2026

CEN

CEN/TC 109 Central heating boilers using gaseous fuels

Technical Specification

27.060.30   Boilers and heat exchangers | 91.140.10   Central heating systems

Scope

Shall be according to EN 15502-2-2:2024, Clause 1 with the following modifications:
Add at the end of the list, after h), the following:
“i) which are atmospheric fully premixed appliances equipped with a Pneumatic Gas supply (PGS) that are intended to be connected to gas grids for natural gases of the second family where up to 20 mol% H2 is added to the natural gas (H2NG-Y20), where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extent over the lifetime of the appliance”
Replace:
“ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;”
with:
“ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas, except for atmospheric fully premixed appliances equipped with a Pneumatic Gas supply (PGS)(which are covered by this document);”

Life cycle

NOW

IN_DEVELOPMENT
FprCEN/TS 15502-3-2
30.99 CD approved for registration as DIS
Jul 31, 2026