ENV 13381-5:2002

Test methods for determining the contribution to the fire resistance of structural members - Part 5: Applied protection to concrete/profiled sheet steel composite members

Publication date:   Oct 23, 2003

General information

99.60 Withdrawal effective   Nov 12, 2014

CEN

CEN/TC 127 Fire safety in buildings

Pre Standard

13.220.50   Fire-resistance of building materials and elements | 91.080.01   Structures of buildings in general

Buying

  Withdrawn

PDF - €43.97

  English  



Buy

Scope

This European Prestandard specifies a test method for determining the contribu-tion of fire protection systems to the fire resistance of structural concrete/profiled sheet steel composite members or slabs. The concrete can be lightweight, normal-weight or heavy-weight concrete and of strength classes 20/25 (LC/C/HC) to 50/60 (LC/C/HC).

The method is applicable to all fire protection systems used for the protection of such structural composite members or slabs and includes sprayed fire protection, coatings, cladding protection systems and multi-layer or composite fire protection materials.

The test method and its assessment procedure are designed to permit direct application of the results to cover a range of thicknesses of the applied fire protection material.

The test method is only applicable to fire protection systems which are fixed directly to the underside of the concrete/steel composite member or slab. Fire protection systems where the fire protection material is not attached directly to the composite member, leading to a continuous cavity between the concrete/steel composite member and the fire protection system of size greater than 5 mm is the subject of prENV 13381-1.

This European Prestandard contains the fire test which specifies the tests which shall be carried out to determine the ability of the fire protection system to remain coherent and fixed to the composite member and to provide data on the temperatures of the steel sheet, throughout the depth of the concrete (for extended application purposes) and the unexposed surface of the concrete, when exposed to the standard temperature/time curve according to the procedures defined herein.

In special circumstances, where specified in national building regulations, there can be a need to subject reactive protection material to a smouldering curve. The test for this and the special circumstances for its use are detailed in annex A.

The fire test methodology makes provision for the colle

Related legislation

Legislation related to this standard

89/106/EEC

Construction products

305/2011

Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec

Life cycle

NOW

WITHDRAWN
ENV 13381-5:2002
99.60 Withdrawal effective
Nov 12, 2014

REVISED BY

PUBLISHED
EN 13381-5:2014