ENV 13381-2:2002

Test methods for determining the contribution to the fire resistance of stuctural members - Part 2: Vertical protective membranes

Publication date:   Oct 23, 2003

General information

99.60 Withdrawal effective   Sep 24, 2014

CEN

CEN/TC 127 Fire safety in buildings

Pre Standard

13.220.50   Fire-resistance of building materials and elements | 13.220.99   Other standards related to protection against fire

Buying

  Withdrawn

PDF - €43.97

  English   Bulgarian  



Buy

Scope

This part of this European Prestandard specifies a test method for determining the ability of a vertical protective membrane, when used as a fire resistant barrier, to contribute to the fire resistance of loadbearing vertical structural building members fabricated from steel, concrete, steel / concrete composites or timber. The method described is applicable to any type of vertical protective membrane, which can be associated with a separate bracing membrane.

The vertical protective membrane can be separate from the structural building member and be self-supporting or can be attached to the structural building member and can form part of any load bearing structure. This test method is applicable to vertical protective membranes where there is a separating gap of at least 5 mm size between the vertical protective membrane and the structural building member, otherwise alternative test methods prENV 13381-3, prENV 13381-4, prENV 13381-6 or prENV 13381-7 should be used as appropriate

This test method and assessment is not applicable to the following:

a) all situations where the cavity behind the vertical protective membrane contains more than a specified amount of combustible materials, e.g. electrical cables and pipes, other than where timber structural members themselves are required;

b) all situations where the cavity is to be used as a service or ventilation shaft;

c) all situations where the vertical protective membrane acts as a bracing membrane.

This European Prestandard contains the fire test which specifies the tests which should be carried out whereby the vertical protective membrane together with the structural member to be protected is exposed to the specified fire. The fire exposure, to the standard temperature/time curve given in EN 1363-1, is applied to the side which would be exposed in practice.

The test method makes provision, through specified optional additional procedures, for the collection of data which can be used as direct

Related legislation

Legislation related to this standard

89/106/EEC

Construction products

305/2011

Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec

Life cycle

NOW

WITHDRAWN
ENV 13381-2:2002
99.60 Withdrawal effective
Sep 24, 2014

REVISED BY

PUBLISHED
EN 13381-2:2014