60.60 Standard published Jun 15, 2010
CEN
CEN/TC 127 Fire safety in buildings
European Norm
13.220.40 Ignitability and burning behaviour of materials and products | 97.150 Floor coverings
ISO 9239-1:2010 specifies a method for assessing the wind-opposed burning behaviour and spread of flame of horizontally mounted floorings exposed to a heat flux radiant gradient in a test chamber, when ignited with pilot flames.
This method is applicable to all types of flooring. e.g. textile carpet, cork, wood, rubber and plastics coverings as well as coatings. Results obtained by this method reflect the performance of the flooring, including any substrate if used. Modifications of the backing, bonding to a substrate, underlay or other changes of the flooring may affect test results.
ISO 9239-1:2010 is applicable to the measurement and description of the properties of floorings in response to heat and flame under controlled laboratory conditions. It should not be used alone to describe or appraise the fire hazard or fire risk of floorings under actual fire conditions.
Legislation related to this standard
Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec
WITHDRAWN
EN ISO 9239-1:2002
PUBLISHED
EN ISO 9239-1:2010
60.60
Standard published
Jun 15, 2010
IN_DEVELOPMENT
prEN ISO 9239-1