EN ISO 16000-10:2006

Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test cell method (ISO 16000-10:2006) EN ISO 16000-10:2006

Publication date:   Aug 10, 2006

General information

90.93   Standard confirmed   Jun 16, 2009

CEN

CEN/TC 264 Air quality

European Norm

13.040.20   Ambient atmospheres

Buying

Published

Language in which you want to receive the document.

Scope

ISO 16000-10:2006 specifies a general laboratory test method for determination of the area specific emission rate of volatile organic compounds (VOCs) from newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to aged products. The emission data obtained can be used to calculate concentrations in a model room.
According to the definition of an emission test cell, it is also possible to perform non-destructive emission measurements on building products on-site in buildings. However, the procedure for such measurements is not described in ISO 16000-10:2006. An example of an emission test cell is described.
ISO 16000-10:2006 is also applicable to wood-based panels and other building products, in order to determine the emission rate of formaldehyde.