EN IEC 60317-60-2:2020

Specifications for particular types of winding wires - Part 60-2: Polyester glass-fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 155 EN IEC 60317-60-2:2020

Publication date:   Dec 21, 2020

General information

60.60 Standard published   Aug 7, 2020

CENELEC

CLC/TC 55 Winding wires

European Norm

29.060.10   Wires

Buying

Published

Language in which you want to receive the document.

Scope

IEC 60317-60-2:2020 specifies the requirements of polyester glass-fibre wound, resin or varnish impregnated, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. The range of nominal conductor dimensions covered by this document is:

– width: min. 2,0 mm max. 16,0 mm;

– thickness: min. 0,80 mm max. 5,60 mm.

NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

Life cycle

NOW

PUBLISHED
EN IEC 60317-60-2:2020
60.60 Standard published
Aug 7, 2020