60.60 Standard published Jun 23, 2017
CENELEC
CLC/TC 111X Environment
European Norm
31.020 Electronic components in general | 71.040.50 Physicochemical methods of analysis
Published
IEC 62321-7-2:2017 describes procedures to measure hexavalent chromium, Cr(VI), quantitatively in samples of polymers and electronics. This method employs organic solvent to dissolve or swell the sample matrix, followed by an alkaline digestion procedure to extract Cr(VI) from samples. Studies have shown that organic/alkaline solution is more effective than acidic solution in extracting Cr(VI) from soluble and insoluble samples. Minimal reduction of Cr(VI) to Cr(III) or oxidation of Cr(III) to Cr(VI) occurs under alkaline conditions. The first edition of IEC 62321:2008 was a ‘stand-alone’ standard that included an introduction, an overview of test methods, a mechanical sample preparation as well as various test method clauses. This first edition of IEC 62321-7-2 is a partial replacement of IEC 62321:2008, forming a structural revision and generally replacing Annex C. IEC 62321-7-2 is the final replacement part of the corresponding clauses in IEC 62321:2008.
WITHDRAWN
EN 62321:2009
PUBLISHED
EN 62321-7-2:2017
60.60
Standard published
Jun 23, 2017