EN 61094-2:2009

Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique EN 61094-2:2009

Publication date:   Aug 21, 2009

General information

60.60 Standard published   Apr 16, 2009

CENELEC

CLC/SR 29 Electroacoustics

European Norm

17.140.50   Electroacoustics

Buying

Published

Language in which you want to receive the document.

Scope

IEC 61094-2:2009 is applicable to laboratory standard microphones meeting the requirements of IEC 61094-1 and other types of condenser microphone having the same mechanical dimensions and specifies a primary method of determining the complex pressure sensitivity so as to establish a reproducible and accurate basis for the measurement of sound pressure. This second edition cancels and replaces the first edition published in 1992. This second edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:<br /> - an update of Clause 6 to fulfil the requirements of ISO/IEC Guide 98-3;<br /> - an improvement of the heat conduction theory in Annex A;<br /> - a revision of Annex F: Physical properties of humid air.

Life cycle

PREVIOUSLY

WITHDRAWN
EN 61094-2:1993

NOW

PUBLISHED
EN 61094-2:2009
60.60 Standard published
Apr 16, 2009

CORRIGENDA / AMENDMENTS

PUBLISHED
EN 61094-2:2009/A1:2022

REVISED BY

IN_DEVELOPMENT
prEN IEC 61094-2