99.60 Withdrawal effective Oct 1, 2007
CENELEC
CLC/TC 210 Electromagnetic Compatibility (EMC)
European Norm
29.020 Electrical engineering in general
Withdrawn
Relates to the immunity requirements and test methods for electrical and electronic equipment to repetitive electrical fast transients. Additionally defines ranges of test levels and establishes test procedures. The object of this standard is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to repetitive fast transients (bursts), on supply, signal and control ports. The test is intended to demonstrate the immunity of electrical and electronic equipment when subjected to types of transient disturbances such as those originating from switching transients (interruption of inductive loads, relay contact bounce, etc.). The standard defines: - test voltage waveform; - range of test levels; - test equipment; - test set-up; - test procedure.
Legislation related to this standard
Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC
WITHDRAWN
EN 61000-4-4:1995
99.60
Withdrawal effective
Oct 1, 2007
WITHDRAWN
EN 61000-4-4:2004