IEC 60811-509:2012 gives the procedure for the test for resistance of insulations and sheaths to cracking at an elevated temperature. IEC 60811-509:2012 cancels and replaces Clause 9 of IEC 60811-3-1:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012. This publication is to be read in conjunction with <a href='http://webstore.iec.ch/webstore/webstore.nsf/ArtNum_PK/46164'>IEC 60811-100:2012</a>.
Legislation related to this standard
Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (codified version)
Harmonized/SupportingDirective 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
Harmonized/Supporting
WITHDRAWN
EN 60811-3-1:1995/A2:2001
WITHDRAWN
EN 60811-3-1:1995
WITHDRAWN
EN 60811-3-1:1995/A1:1996
PUBLISHED
EN 60811-509:2012
60.60
Standard published
Jun 15, 2012
PUBLISHED
EN 60811-509:2012/A1:2017