Specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for ignitability testing to determine the glow-wire ignition temperature (GWIT). The test results make it possible to provide a relative comparison of various materials according to the temperature at which the test specimen ignites during the application of the electrically heated glow-wire used as an ignition source. The test method is not valid for determining the ignition behaviour of complete items of equipment, since the dimensions of the insulating systems or combustible parts, the design and heat transfer to adjacent metallic or non-metallic parts, etc., greatly influence the ignitability of the materials used therein. In addition to this, it is not valid for determining fire behaviour and fire hazard of equipment. Has the status of a basic safety publication in accordance with IEC Guide 104.
Legislation related to this standard
Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (codified version)
Harmonized/Supporting
WITHDRAWN
EN 60695-2-1/3:1996
WITHDRAWN
EN 60695-2-13:2001
99.60
Withdrawal effective
Dec 1, 2013
WITHDRAWN
EN 60695-2-13:2010