IEC 60317-33:2015(E) specifies the requirements of polyester glass fibre wound, impregnated, bare or enamelled rectangular copper winding wire, temperature index 200. The range of nominal conductor dimensions covered by this standard is:
- width: min 2,0 mm max 16,0 mm;
- thickness: min 0,80 mm max 5,60 mm. The specified combinations of width and thickness as well as the specified width/thickness ratio are according to IEC 60317-0-4. This second edition cancels and replaces the first edition published in 1990, Amendment 1:1997 and Amendment 2:2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new 3.2.2 containing general notes on winding wire, formerly part of the scope;
- introduction of glass fibre coverings over grade 1 enamelled conductor in 3.2.2;
- revision to references to IEC 60317-0-4 to make clear that their application is normative.
Keywords: temperature index 200, winding wire
WITHDRAWN
EN 60317-33:1996
WITHDRAWN
EN 60317-33:1996/A2:2005
WITHDRAWN
EN 60317-33:1996/A1:1997
PUBLISHED
EN 60317-33:2016
60.60
Standard published
Jan 22, 2016