60.60 Standard published Jan 22, 2016
CENELEC
CLC/TC 210 Electromagnetic Compatibility (EMC)
European Norm
33.040.60 Powerline telecommunications
Published
This part of EN 50561 specifies limits and methods of measurement of radio disturbance characteristics for in-home communication apparatus that use the low voltage power installation as the transmission medium. This part of EN 50561 applies to equipment that uses frequencies including those above 30 MHz in order to communicate.
Procedures are given for the measurement of signals generated by the equipment and limits are specified within the frequency range 9 kHz to 400 GHz. No measurement is required at frequencies where no limits are specified.
The radiated emission requirements in this standard are not intended to be applicable to the intentional transmissions from a radio-transmitter as defined by the ITU, nor to any spurious emissions related to these intentional transmissions.
NOTE The requirements defined in this standard effectively restrict the intended transmission frequencies to below 87,5 MHz.
Legislation related to this standard
Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity
Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC
Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)
Directive 2014/53/EU of The European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999/5/EC
PUBLISHED
EN 50561-3:2016
60.60
Standard published
Jan 22, 2016
IN_DEVELOPMENT
prEN 50561-3