60.60 Standard published Oct 18, 2013
CENELEC
CLC/TC 210 Electromagnetic Compatibility (EMC)
European Norm
33.040.60 Powerline telecommunications
This part of EN 50561 specifies limits and methods of measurement of radio disturbance characteristics for in-home communication apparatus that use the low-voltage power installation as the transmission medium. This part of EN 50561 applies to equipment that communicate over this medium in the frequency range 1,606 5 MHz to 30 MHz.
NOTE Similar equipment that communicate outside this frequency range is under study and will be covered by another European Standard.
Procedures are given for the measurement of signals generated by the equipment and limits are specified for the frequency range 9 kHz to 400 GHz. No measurement is required at frequencies where no limit is specified.
Legislation related to this standard
Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity
Harmonized/SupportingDirective 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC
Harmonized/SupportingDirective 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)
Harmonized/SupportingDirective 2014/53/EU of The European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999/5/EC
WITHDRAWN
EN 55022:2010
WITHDRAWN
EN 55032:2012
WITHDRAWN
EN 55032:2012/AC:2013
WITHDRAWN
EN 55022:2010/AC:2011
PUBLISHED
EN 50561-1:2013
60.60
Standard published
Oct 18, 2013
IN_DEVELOPMENT
prEN 50561-1