This European Standard applies to single core, crosslinked elastomer covered arc welding cables. The cables are of rated voltage U0/U 100/100 V. The cables are intended for connections between the welding power source and the electrode holder and the work piece. Two types of cable are included, with respectively Class D and Class E conductors. These conductors are more flexible than Class 6 to EN 60228, with Class E having the greater flexibility. The maximum conductor operating temperature for each of the cables in this standard is 85 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard, and gives specific current ratings and volt drop data. This EN 50525-2-81 should be read in conjunction with EN 50525-1, which specifies general requirements.
Legislation related to this standard
Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (codified version)
Harmonized/SupportingDirective 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
Harmonized/Supporting
WITHDRAWN
HD 22.6 S2:1995/A1:1999
WITHDRAWN
HD 22.6 S2:1995/corrigendum Jun. 1995
WITHDRAWN
HD 22.6 S2:1995
WITHDRAWN
HD 22.6 S2:1995/A2:2004
PUBLISHED
EN 50525-2-81:2011
90.93
Standard confirmed
Oct 23, 2024