EN 50465:2008

Gas appliances - Fuel cell gas heating appliances - Fuel cell gas heating appliance of nominal heat input inferior or equal to 70 kW EN 50465:2008

Publication date:   Dec 30, 2008

General information

99.60 Withdrawal effective   Oct 29, 2017

CEN/CENELEC

CEN/CLC/JWG FCGA Fuel cell gas appliances

European Norm

27.070   Fuel cells | 97.100.99   Heaters using other sources of energy

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This European Standard applies to the construction, the safety, the functional requirements and the test methods, as well as the classification and the marking of a fuel cell gas heating appliance, which will be operated predominantly heat followed, meeting the following boundary conditions:
– maximum heat load (gas input): 70 kW
– maximum electrical output: 11 kW.
NOTE Due to the fact, that there are national deviations on the maximum electrical output in Europe, this maximum electrical output is independent referring the number of connected phases to the public low voltage grid.
– fuel: combustion gas in accordance with EN 437
– maximum heating water temperature: 95 °C (under normal operational conditions)
– process pressures in the fuel cell gas appliance:
– heating water: max. 6 bar
– domestic hot water (if installed): max. 10 bar
– device construction: According to the expositions in accordance with CEN/TR 1749, EN 483 or EN 297 (B22, B23, B32, B33, C12, C13, C32, C33, C42, C43, C52, C53, C62, C63, C82, C83) ).
This European Standard applies to type testing only.
This European Standard does not contain the requirements necessary for appliances for producing electrical energy without thermal energy.

Related legislation

Legislation related to this standard

90/396/EEC

Appliances burning gaseous fuels

2009/142/EC

Appliances burning gaseous fuels

Life cycle

NOW

WITHDRAWN
EN 50465:2008
99.60 Withdrawal effective
Oct 29, 2017

REVISED BY

PUBLISHED
EN 50465:2015