EN 50264-3-1:2008

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables EN 50264-3-1:2008

Publication date:   Sep 5, 2008

General information

90.93 Standard confirmed   Sep 29, 2021

CENELEC

CLC/TC 20 Electric cables

European Norm

13.220.20   Fire protection | 29.060.20   Cables | 45.060.01   Railway rolling stock in general

Buying

Published

Language in which you want to receive the document.

Scope

EN 50264-3-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2); • 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2); • 1,8/3 kV unscreened, sheathed (1,5 mm2 to 400 mm2); • 3,6/6 kV unscreened, sheathed (2,5 mm2 to 400 mm2). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90° C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-3-1 should be read in conjunction with Part 1 “General requirements”.

Life cycle

NOW

PUBLISHED
EN 50264-3-1:2008
90.93 Standard confirmed
Sep 29, 2021