99.60 Withdrawal effective Nov 1, 2007
CENELEC
CLC/TC 210 Electromagnetic Compatibility (EMC)
European Norm
17.220 Electricity. Magnetism. Electrical and magnetic measurements | 29.020 Electrical engineering in general
There are many different test sites and facilities that have been constructed to make radiated emission measurements at frequencies above 30 MHz according to CISPR 16-1. Most are protected from the weather and the adverse effects of the radio frequency ambient noise. These include all weather covered open area test sites and absorber lined shielded enclosures. Whenever construction material encloses a test site, there exists the possibility that the result of a single normalized site attenuation measurement as specified in subclause 16.6 of CISPR 16-1 is not adequate to show such alternate site suitability NOTE: Radiated emission sources located near dielectric interfaces have been shown to have variations in current distribution that can affect the radiated properties of the source at that location. When the EUT can be located near these interfaces, additional site attenuation measurements are required. This standard specifies requirements for alterneative test sites regarding site attenuation. As long as the document CISPR/A(CO)63 is not published as part of CISPR 16, this standard shall be used for test site qualification.
Legislation related to this standard
Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC
WITHDRAWN
EN 50147-2:1996
99.60
Withdrawal effective
Nov 1, 2007